Evidence map›Paper›PMID 36424734›Full record

ArticleOrthopaedic surgery2023

Finite Element Analysis and Transiliac-Transsacral Screw Fixation for Posterior Pelvic Ring with Sacrum Dysplasia.

Chao Wu, Baifang Zeng, Jiayan Deng, Binwei Qin, Danwei Shen, Xiangyu Wang, Haigang Hu, Li Huang, Xin Liu, Guigang Qiu

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 11 citations in OpenAlex.

  1. Percutaneous fixation of posterior pelvic ring lesions in the elderly: current evidence and recent advances.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Review
  2. Article
  3. Sacroiliac fixation in pediatric patients: stability analysis by the finite element method.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
    Article
  4. Article
  5. Novel 3D-navigated screw corridors for posterior pelvic ring stabilization: a finite element analysis.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Chao WuDepartment of Orthopaedics, Zigong Fourth People's Hospital, Zigong, China.ORCID https://orcid.org/0000-0002-7215-1460
Baifang ZengDepartment of Orthopaedics, Zigong Fourth People's Hospital, Zigong, China.
Jiayan DengInstitute of Digital Medicine, Zigong Academy of Big Data for Medical Science and Artificial Intelligence, Zigong, China.
Binwei QinDepartment of Orthopaedics, Zigong Fourth People's Hospital, Zigong, China.
Danwei ShenInstitute of Digital Medicine, Zigong Academy of Big Data for Medical Science and Artificial Intelligence, Zigong, China.
Xiangyu WangDepartment of Orthopaedics, Zigong Fourth People's Hospital, Zigong, China.
Haigang HuDepartment of Orthopaedics, Zigong Fourth People's Hospital, Zigong, China.
Li HuangOperation Center, Zigong Fourth People's Hospital, Zigong, China.
Xin LiuHealth Management Center, Zigong Fourth People's Hospital, Zigong, China.
Guigang QiuDepartment of Orthopaedics, Zigong Fourth People's Hospital, Zigong, China.
Zigong First People's Hospital · CNBeijing Academy of Artificial Intelligence · CNAffiliated Hospital of Southwest Medical University · CN

Funding

Science and Technology Cooperation Project between Sichuan University and Zigong 2021CDZG-22Science and Technology Project of Sichuan Medical Association 2021SAT02Zigong Key Science and Technology Program 2020RKX08Zigong Key Science and Technology Program 2022ZCYGY04
6 · The paper itself

Abstract

objectivePosterior pelvic ring sacroiliac screws are preferred by clinicians for their good biomechanical performance. However, there are few studies on mechanical analysis and intraoperative screw insertion of the dysplastic sacrum and sacroiliac screw. This study investigated the biomechanical performance of oblique sacroiliac screws (OSS) in S1 combined with transiliac-transsacral screws (TTSs) in S2 for pelvic fracture or sacroiliac dislocation with dysplastic sacrum and evaluated the safety of screw placement assisted by the navigation template.

methodsSix models were established, including one OSS fixation in the S2 segment, one transverse sacroiliac screw (TSS) fixation in the S2 segment, one TTS fixation in the S2 segment, one OSS fixation in the S1 and S2 segments, one OSS fixation in the S1 segment and one TSS fixation in the S2 segment, one OSS fixation in the S1 segment and one TTS fixation in the S2 segment. Then, finite element analysis (FEA) was performed. Twelve dysplastic sacrum patients with pelvis fracture or sacroiliac dislocation underwent OSS insertion in the S1 combined with TTS insertion in the S2 under the assistance of the patient-specific locked navigation template. Grading and Matta scores were evaluated after surgery.

resultsIn the one-screw fixation group, the vertical displacements of the sacrum surface of S2 OSS, S2 TSS and S2 TTS were 1.23, 1.42, and 1.22 mm, respectively, and the maximum stress of screw were 139.45 MPa, 144.81 MPa, 126.14 MPa, respectively. In the two-screw fixation group, the vertical displacements of the sacrum surface of the S1 OSS + S2 OSS, S1 OSS + S2 TSS and S1 OSS + S2 TTS were 0.91, 1.06, and 0.75 mm, respectively, and the maximum stress of screw were 149.26 MPa, 167.13 Pa, 136.76 MPa, respectively. Clinically, a total of 12 TTS and OSS were inserted under the assistance of navigation templates, with a surgical time of 55 ± 7.69 min, bleeding of 57.5 ± 18.15 ml and radiation times of 14.5 ± 4.95. One of the TTS and one of the OSS were grade 1, and the other screws were grade 0. The Matta scores of nine patients were excellent, and three patents were good.

conclusionOSS in the S1 combined with TTS in the S2 had the best mechanical stability in six models, and it is safe for screw insertion assisted by the patient-specific locked navigation template.

Indexed as

Fractures, BoneJoint DislocationsPelvic BonesBone ScrewsFinite Element AnalysisFracture Fixation, InternalHumansIliumPelvisSacrum3D printingDysplasia sacrumFEAPelvic ring injuriesTransverse sacroiliac screw

Identifiers

PMID36424734
PMCPMC9837241
OpenAlexW4310047381

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.