Evidence map›Paper›PMID 36424555›Full record

ArticleBMC oral health2022

Evaluation of design, mechanical properties, and torque/force generation of heat-treated NiTi glide path instruments.

Soram Oh, Ji-Yeon Seo, Ji-Eun Lee, Hyun-Jung Kim, Ji-Hyun Jang, Seok Woo Chang

Abstract read
In one paragraph

Article in BMC oral health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Soram OhDepartment of Conservative Dentistry, Kyung Hee University Medical Center, 23 Kyungheedae-Ro, Dongdaemun-Gu, Seoul, 02447, Republic of Korea.
Ji-Yeon SeoPrivate Dental Clinic, Seoul, Republic of Korea.
Ji-Eun LeeSeoul Strong Dental Clinic, 35 Bonghwasan-Ro, Jungnang-Gu, Seoul, 02017, Republic of Korea.
Hyun-Jung KimDepartment of Conservative Dentistry, Kyung Hee University Medical Center, 23 Kyungheedae-Ro, Dongdaemun-Gu, Seoul, 02447, Republic of Korea.
Ji-Hyun JangDepartment of Conservative Dentistry, Kyung Hee University Medical Center, 23 Kyungheedae-Ro, Dongdaemun-Gu, Seoul, 02447, Republic of Korea.
Seok Woo ChangDepartment of Conservative Dentistry, Kyung Hee University Medical Center, 23 Kyungheedae-Ro, Dongdaemun-Gu, Seoul, 02447, Republic of Korea. swc2007smc@khu.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecently, various kinds of heat-treated nickel-titanium (NiTi) glide path instruments have been manufactured. This study aimed to investigate design, phase transformation behavior, mechanical properties of TruNatomy Glider (#17/02), V Taper 2H (#14/03), and HyFlex EDM (#15/03) and compare torque/force generated during simulated glide path preparation with them.

methodsThe designs and phase-transformation behaviors of the instruments were examined via scanning electron microscopy (n = 3) and differential scanning calorimetry (n = 2). Their bending (n = 15), torsional (n = 15), and cyclic fatigue resistances (n = 15) were tested. The ultimate strength and distortion angle were obtained from torsional resistance test. The number of cycles to failure (NCF) was calculated from cyclic fatigue resistance test. The preparation of the glide path was simulated using a double-curved artificial canal (n = 15), and the maximum torque and screw-in forces were measured. Data except NCF was compared between brands with one-way ANOVA with Tukey's honestly significant difference test. NCF was analyzed via Kruskal-Wallis and Mann-Whitney U tests.

resultsTruNatomy Glider had the greatest number of threads. TruNatomy Glider showed progressive taper, while V Taper 2H and HyFlex EDM had constant taper. The austenitic transformation-finish temperatures of all the instruments were above body temperature. V Taper 2H demonstrated significantly lower ultimate strength, higher distortion angle, and a higher number of cycles to failure compared with HyFlex EDM and TruNatomy Glider (p < 0.05). The maximum torque generated during preparing glide path was lowest for V Taper 2H, and the maximum screw-in force was lowest for HyFlex EDM (p < 0.05). TruNatomy Glider generated the highest torque and screw-in force during the apical preparation.

conclusionsV Taper 2H #14/03 showed superior cyclic fatigue resistance and lower ultimate strength. TruNatomy Glider generated greater clockwise torque and screw-in force during apical preparation. The mechanical properties, torque, and screw-force was affected by design of heat-treated glide path instruments. Cervical pre-flaring prior to glide path instrument is recommended.

Indexed as

NickelTitaniumAlloysHot TemperatureHumansTorqueAlloysNickelnitinolTitaniumtitanium nickelideGlide pathHeat treatmentMechanical testNiTi instrumentScrew-in forceTorque

Identifiers

PMID36424555
PMCPMC9686033

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.