Evidence map›Paper›PMID 36423234›Full record

ArticleJournal of cardiovascular electrophysiology2023

Spatial relationship of localized sources of persistent atrial fibrillation identified by a unipolar-based automated algorithm to complex fractionated atrial electrocardiograms and atrial low voltage areas.

Takahiko Nagase, Ryuichi Kato, So Asano, Hiroshi Fukunaga, Yoshinori Yoshida, Yosuke Hayashi, Yukio Sekiguchi, Mamoru Nanasato, Junichi Nitta, Mitsuaki Isobe

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of cardiovascular electrophysiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Comparison of voltages between atria: differences in sinus rhythm and atrial fibrillation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2024
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Takahiko NagaseDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Ryuichi KatoDepartment of Cardiology, Higashiyamato Hospital, Tokyo, Japan.
So AsanoDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Hiroshi FukunagaDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.ORCID 0000-0001-6094-5151
Yoshinori YoshidaDepartment of Cardiology, Higashiyamato Hospital, Tokyo, Japan.
Yosuke HayashiDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Yukio SekiguchiDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Mamoru NanasatoDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Junichi NittaDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Mitsuaki IsobeSakakibara Heart Institute, Tokyo, Japan.
Sakakibara Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionSpatial characteristics of localized sources of persistent atrial fibrillation (AF) identified by unipolar-based panoramic mapping software (CARTOFINDER) remain unclear. We evaluated spatial characteristics of bi-atrial AF localized sources in relation to complex fractionated atrial electrocardiograms (CFAEs) and atrial low voltage area (LVAs) (≤0.35 mV during AF). METHODS AND

resultsTwenty consecutive patients with persistent AF underwent bi-atrial voltage, CFAE, and CARTOFINDER mapping before the beginning of ablation (18 [90%] patients, initial procedure; 2 [10%] patients, repeat procedure). CFAEs were recorded using the interval confidence level (ICL) mode and defined as sites with a confidence level of ≥80% of maximal ICL number. We elucidated the following: (1) differences in the rate of AF localized sources and CFAEs inside or outside the atrial LVAs; (2) distribution of AF localized sources and CFAEs; and (3) distance between the closest points of AF localized sources and CFAEs. A total of 270 AF localized sources and 486 CFAEs were identified in 20 patients. AF localized sources were confirmed more often outside atrial LVAs than CFAEs (71% vs. 46% outside LVA, p < .001). AF localized sources and CFAEs were diffusely distributed without any tendency in bi-atria. Mean distance between closest AF localized sources and CFAEs was 22 ± 8 mm.

conclusionAF localized sources identified by CARTOFINDER are different therapeutic targets as compared to CFAEs and could be confirmed both inside and outside atrial LVAs.

Indexed as

Atrial FibrillationCatheter AblationAlgorithmsElectrocardiographyHeart AtriaHumansatrial fibrillationcomplex fractionated atrial electrocardiogramlocalized sourceslow voltage areaspatial relationship

Identifiers

PMID36423234
OpenAlexW4309902869

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked