A Numerical Investigation on Hydrothermal Performance of Micro Channel Heat Sink with Periodic Spatial Modification on Sidewalls.

Nikita Kumari, Tabish Alam, Masood Ashraf Ali, Anil Singh Yadav, Naveen Kumar Gupta, Md Irfanul Haque Siddiqui, Dan Dobrotă, Ionela Magdalena Rotaru, Abhishek Sharma

Abstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Nikita KumariSchool of Automation, Banasthali Vidyapith, Jaipur 304022, India.
Tabish AlamCSIR-Central Building Research Institute, Roorkee 247667, India.ORCID 0000-0001-7772-1015
Masood Ashraf AliDepartment of Industrial Engineering, College of Engineering, Prince Sattam Bin Abdulaziz University, Al-Kharj 16273, Saudi Arabia.ORCID 0000-0002-1426-5339
Anil Singh YadavMechanical Engineering Department, IES College of Technology, Bhopal 462044, India.ORCID 0000-0001-6786-2180
Naveen Kumar GuptaMechanical Engineering Department, Institute of Engineering & Technology, GLA University, Mathura 281406, India.
Md Irfanul Haque SiddiquiMechanical Engineering Department, King Saud University, Riyadh 11421, Saudi Arabia.ORCID 0000-0003-4289-4826
Dan DobrotăFaculty of Engineering, Department of Industrial Engineering and Management, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.ORCID 0000-0002-2202-7701
Ionela Magdalena RotaruFaculty of Engineering, Department of Industrial Engineering and Management, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
Abhishek SharmaDepartment of Mechanical Engineering, Birsa Institute of Technology Sindri, Dhanbad 828123, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electronic gadgets have been designed to incorporating very small components such as microcontrollers, electronic chips, transistors, microprocessors, etc. These components are exceptionally heat sensitive and can be wrecked if heat is not released. As a result, the thermal control of such components is critical to their optimum performance and extended life. The use of a microchannel heat sink (MCHS) has shown promising solutions to remove the excess heat. In this paper, we have proposed a novel design of MCHS and investigated it numerically. Four different surface modifications on the sidewall of the passage, namely, extended triangular surface (ETS), extended circular surface (ECS), triangular groove surface (TGS), and the circular groove surface (CGS) in the passage of the microchannel have been exploited in the Reynolds number of 100-900. In the presence of geometrical modification, the cooling capacities have been enhanced. The results show that the Nusselt numbers of ETS-MCHS, ECS-MCHS, TGS-MCHS, and CGS-MCHS are increased by 4.30, 3.61, 1.62, and 1.41 times in comparison to the Nusselt number of MCHS with smooth passage, while the friction factor values are increased by 7.33, 6.03, 2.74, and 1.68 times, respectively. In addition, the thermohydraulic performance parameter (THPP) has been evaluated and discussed. The fact that MCHS have THPP values greater than unity demonstrates that the passage's geometries are a practical means of achieving effective thermal management.

Indexed as

hydrothermal performancemicrochannel heat sink (MCHS)Nusselt numberthermal resistance