ArticleMembranes2022
A New Sensing Material Based on Tetraaza/SBA15 for Rapid Detection of Copper(II) Ion in Water.
Article in Membranes, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
A novel rapid and sensitive optical sensor for Cu2+ ion detection based on 5,5,7,12,12,14-hexamethyl-1,4,8,11-tetraazacyclotetradeca-7,14-dienium dibromide (TL) immobilized on Santa Barbara Amorphous (SBA-15) has been successfully developed. The inner and outer space of SBA15 allowed a high capacity of TL compound to immobilize onto it. FESEM (Field Emission Scanning Electron Microscopy) analysis was performed to confirm the morphology of TL-SBA15, while FTIR (Fourier Transform Infrared Spectroscopy) was utilized to confirm the interaction of TL−SBA15. A binding study of TL compound towards Cu2+ ion was performed via UV-vis solution study and binding titration. The stoichiometric binding ratio and binding constant value Kb of TL towards Cu2+ ion was 1:1 and 2.33 × 103 M−1, respectively. The optical reflectance sensor based on the TL compound is selective to Cu2+ ion and demonstrated a linear response over a Cu2+ ion concentration range of 1 × 10−7 M to 2 × 10−5 M, with a detection limit (LOD) of 1.02 × 10−7 M (R2 = 0.99) and fast response time of < 1 min. It showed high reproducibility, with a relative standard deviation (RSD) obtained at 0.47%. This optical sensor is reusable up to five consecutive times on Cu2+ ion by using 0.1 M EDTA with a pH of 6 as a regeneration solution, with a reversibility RSD value of 0.79%. The developed optical sensor provides a rapid and sensitive tool for Cu2+ ion detection in teabag samples, and the results align with those obtained by the ICP-MS standard method.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.