Evidence map›Paper›PMID 36421223›Full record

ArticleChildren (Basel, Switzerland)2022

A Comparison of the bébé VieScope™ and Direct Laryngoscope for Use While Wearing PPE-AGP: A Randomized Crossover Simulation Trial.

Pawel Wieczorek, Lukasz Szarpak, Agata Dabrowska, Michal Pruc, Alla Navolokina, Andrzej Raczynski, Jacek Smereka

Open access · goldAbstract read
In one paragraph

Article in Children (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.0field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 3 countries.

Pawel WieczorekPediatric Intensive Care Unit (PICU), John Paul II Upper Silesian Health Centre in Katowice, 40-752 Katowice, Poland.ORCID 0000-0002-7159-4040
Lukasz SzarpakResearch Unit, Maria Sklodowska-Curie Bialystok Oncology Center, 15-027 Bialystok, Poland.ORCID 0000-0002-0973-5455
Agata DabrowskaDepartment of Rescue and Disaster Medicine, Poznan University of Medical Sciences, 60-806 Poznan, Poland.
Michal PrucResearch Unit, Polish Society of Disaster Medicine, 05-806 Warsaw, Poland.ORCID 0000-0002-2140-9732
Alla NavolokinaEuropean School of Medicine, International European University, 03187 Kyiv, Ukraine.
Andrzej RaczynskiDepartment of Emergency Medical Service, Wroclaw Medical University, 52-443 Wroclaw, Poland.
Jacek SmerekaResearch Unit, Polish Society of Disaster Medicine, 05-806 Warsaw, Poland.ORCID 0000-0002-1427-4796
Wroclaw Medical University · PLEuropean University · UAJohn Paul II Hospital · PLMedical University of Białystok · PLPoznan University of Medical Sciences · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to compare the intubation effectiveness of the bébé Vie Scope™ (VieScope) and direct laryngoscopy for emergency intubation in a pediatric manikin model performed by paramedics with and without personal protective equipment for aerosol generating procedures (PPE-AGP). Participants performed endotracheal intubation using VieScope and standard Macintosh laryngoscope (MAC) in two research scenarios: (1) without PPE-AGP, and (2) with PPE-AGP. Fifty-one paramedics without any previous experience with the VieScope participated in this study. In the PPE-AGP scenario, in the VieScope group, the percentage of successful tracheal intubation on the first attempt was higher compared to the MAC group (94.1 vs. 78.4%, p = 0.031), intubation time was shorter (29.8 vs. 33.9 s, p < 0.001), and percentage of glottic opening (POGO) score was higher 91.0 vs 77.8 (p < 0.001). On the Cormack−Lehane scale, intubation with VieScope intubation was associated with higher scores rated at 1 (64.7 vs. 29.4%) than in the MAC group (p = 0.001). For intubation in the non-PPE scenario, there were no statistically significant differences between VieScope and MAC in relation to above parameters. Summarize, the bébé VieScope™ under PPE-AGP wearing conditions has proven to be a useful device for airway management in children providing better visualization of the larynx, better intubation conditions, and a higher success rate of tracheal intubation on the first attempt and reduced intubation time compared to the standard Macintosh laryngoscope.

Indexed as

direct laryngoscopyendotracheal intubationFPSintubation timeMacintosh laryngoscopemedical simulationpediatricsuccess rateVieScope

Identifiers

PMID36421223
PMCPMC9689205
OpenAlexW4309788029

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.