Evidence map›Paper›PMID 36421151›Full record

ArticleBiosensors2022

Demonstrating a Filter-Free Wavelength Sensor with Double-Well Structure and Its Application.

Yong-Joon Choi, Kakeru Nakano, Tomoya Ide, Tsugumi Sakae, Ryosuke Ichikawa, Takeshi Hizawa, Daisuke Akai, Kazuhiro Takahashi, Toshihiko Noda, Kazuaki Sawada

Abstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yong-Joon ChoiDepartment of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Japan.ORCID 0000-0003-1063-3752
Kakeru NakanoDepartment of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Japan.
Tomoya IdeDepartment of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Japan.
Tsugumi SakaeDepartment of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Japan.
Ryosuke IchikawaDepartment of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Japan.
Takeshi HizawaOffice for Technical Support Services, Toyohashi University of Technology, Toyohashi 441-8580, Japan.
Daisuke AkaiOffice for Technical Support Services, Toyohashi University of Technology, Toyohashi 441-8580, Japan.ORCID 0000-0003-1178-1255
Kazuhiro TakahashiDepartment of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Japan.
Toshihiko NodaDepartment of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Japan.
Kazuaki SawadaDepartment of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Japan.

Funding

JSPS KAKENHI JP18H03778JSPS KAKENHI JP20K14790JST OPERA JPMJOP1834
6 · The paper itself

Abstract

This study proposed a filter-free wavelength sensor with a double-well structure for detecting fluorescence without an optical filter. The impurity concentration was optimized and simulated to form a double-well-structured sensor, of which the result was consistent with the fabricated sensor. Furthermore, we proposed a novel wavelength detection method using the current ratio based on the silicon absorption coefficient. The results showed that the proposed method successfully detected single wavelengths in the 460-800 nm range. Additionally, we confirmed that quantification was possible using the current ratio of the sensor for a relatively wide band wavelength, such as fluorescence. Finally, the fluorescence that was emitted from the reagents ALEXA488, 594, and 680 was successfully identified and quantified. The proposed sensor can detect wavelengths without optical filters, which can be used in various applications in the biofield, such as POCT as a miniaturized wavelength detection sensor.

Indexed as

SiliconFluorescenceSiliconcentroid wavelengthdouble-wellfilter-freefluorescence detectionfluorescent reagentmultiplexphotogate type sensorwavelength detection

Identifiers

PMID36421151
PMCPMC9688660

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.