Evidence map›Paper›PMID 36421146›Full record

ArticleBiosensors2022

A Reversible Optical Sensor Film for Mercury Ions Discrimination Based on Isoxazolidine Derivative and Exhibiting pH Sensing.

Reham Ali, Siwar Ghannay, Sabri Messaoudi, Fahad M Alminderej, Kaïss Aouadi, Sayed M Saleh

Abstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Reham AliDepartment of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia.ORCID 0000-0003-3104-7613
Siwar GhannayDepartment of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia.
Sabri MessaoudiDepartment of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia.
Fahad M AlminderejDepartment of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia.ORCID 0000-0002-3649-0190
Kaïss AouadiDepartment of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia.
Sayed M SalehDepartment of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia.ORCID 0000-0002-2677-0439

Funding

Qassim University QU-IF-4-3-2-29870
6 · The paper itself

Abstract

We developed a new optical sensor for tracing Hg(II) ions. The detection affinity examines within a concentration range of 0-4.0 µM Hg(II). The sensor film is based on Methyl 2-hydroxy-3-(((2S,2'R,3a'S,5R)-2-isopropyl-5,5'-dimethyl-4'-oxotetrahydro-2'H-spiro[cy-clohexane-1,6'-im-idazo[1,5-b]isoxazol]-2'-yl)methyl)-5-methylbenzoate (IXZD). The novel synthesized compound could be utilized as an optical turn-on chemosensor for pH. The emission intensity is highly enhanced for the deprotonated form concerning the protonated form. IXZD probe has a characteristic fluorescence peak at 481 nm under excitation of 351 nm with large Stocks shift of approximately 130 nm. In addition, the binding process of IXZD:Hg(II) presents a 1:1 molar ratio which is proved by the large quench of the 481 nm emission peak of IXZD and the growth of a new emission peak at 399 nm (blue shift). The binding configurations with one Hg(II) cation and its electronic characteristics were investigated by applying the Density Functional Theory (DFT) and the time-dependent DFT (TDDFT) calculations. Density functional theory (DFT) and the time-dependent DFT (TDDFT) theoretical results were provided to examine Hg(II)-IXZD structures and their electronic properties in solution. The developed chemical sensor was offered based on the intramolecular charge transfer (ICT) mechanism. The sensor film has a significantly low limit of detection (LOD) for Hg(II) of 0.025 μM in pH 7.4, with a relative standard deviation RSD

Indexed as

MercuryHydrogen-Ion ConcentrationIonsLimit of DetectionSpectrometry, FluorescenceIonsMercuryDFTESIPTHg(II)optical sensorpHratiometric

Identifiers

PMID36421146
PMCPMC9688351

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.