Evidence map›Paper›PMID 36421093›Full record

ArticleBioengineering (Basel, Switzerland)2022

PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms.

Nabil Ibtehaz, Sakib Mahmud, Muhammad E H Chowdhury, Amith Khandakar, Muhammad Salman Khan, Mohamed Arselene Ayari, Anas M Tahir, M Sohel Rahman

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers.

0numbers the graph read from it
0cells of the map it votes in
35citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

35 citing papers in PubMed.

  1. Arterial blood pressure waveform reconstruction estimation from PPG using TCN-BiLSTM.American heart journal plus : cardiology research and practice · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nabil IbtehazDepartment of Computer Science, Purdue University, West Lafayette, IN 47907, USA.
Sakib MahmudDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0002-4599-2192
Muhammad E H ChowdhuryDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0003-0744-8206
Amith KhandakarDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0001-7068-9112
Muhammad Salman KhanDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0001-9709-8179
Mohamed Arselene AyariDepartment of Civil and Architectural Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0002-8663-886X
Anas M TahirDepartment of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
M Sohel RahmanDepartment of CSE, BUET, ECE Building, West Palashi, Dhaka 1205, Bangladesh.ORCID 0000-0001-9419-6478

Funding

Qatar National Research Fund NPRP12S-0227-190164Qatar University QUST-2-CENG-2022-711
6 · The paper itself

Abstract

Cardiovascular diseases are one of the most severe causes of mortality, annually taking a heavy toll on lives worldwide. Continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, introducing several layers of complexities and reliability concerns due to non-invasive techniques not being accurate. This motivates us to develop a method to estimate the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using Photoplethysmogram (PPG) signals. We explore the advantage of deep learning, as it would free us from sticking to ideally shaped PPG signals only by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present PPG2ABP, a two-stage cascaded deep learning-based method that manages to estimate the continuous ABP waveform from the input PPG signal with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude, and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP), and Systolic Blood Pressure (SBP) from the estimated ABP waveform outperform the existing works under several metrics (mean absolute error of 3.449 ± 6.147 mmHg, 2.310 ± 4.437 mmHg, and 5.727 ± 9.162 mmHg, respectively), despite that PPG2ABP is not explicitly trained to do so. Notably, both for DBP and MAP, we achieve Grade A in the BHS (British Hypertension Society) Standard and satisfy the AAMI (Association for the Advancement of Medical Instrumentation) standard.

Indexed as

blood pressurecuff-less blood pressuremobile healthPhotoplethysmogram (PPG)regression

Identifiers

PMID36421093
PMCPMC9687508

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.