Evidence map›Paper›PMID 36421088›Full record

ArticleBioengineering (Basel, Switzerland)2022

A Surrogate Model Based on a Finite Element Model of Abdomen for Real-Time Visualisation of Tissue Stress during Physical Examination Training.

Florence Leong, Chow Yin Lai, Siamak Farajzadeh Khosroshahi, Liang He, Simon de Lusignan, Thrishantha Nanayakkara, Mazdak Ghajari

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Machine Learning for Biomedical Applications.Bioengineering (Basel, Switzerland) · 2024
    Article
  2. Soft tissue material properties based on human abdominalFrontiers in bioengineering and biotechnology · 2024
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Florence LeongDyson School of Design Engineering, Imperial College London, London SW7 2DB, UK.ORCID 0000-0002-2516-9625
Chow Yin LaiDepartment of Electronic and Electrical Engineering, University College London, London WC1E 7JE, UK.
Siamak Farajzadeh KhosroshahiSchool of Engineering and Materials Science, Queen Mary University of London, London E1 4NS, UK.ORCID 0000-0003-4476-2579
Liang HeOxford Robotics Institute, University of Oxford, Oxford OX1 3PJ, UK.ORCID 0000-0002-4493-4660
Simon de LusignanNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford OX2 6GG, UK.ORCID 0000-0002-8553-2641
Thrishantha NanayakkaraDyson School of Design Engineering, Imperial College London, London SW7 2DB, UK.
Mazdak GhajariDyson School of Design Engineering, Imperial College London, London SW7 2DB, UK.

Funding

Engineering and Physical Sciences Research Council EP/T00603X/1
6 · The paper itself

Abstract

Robotic patients show great potential for helping to improve medical palpation training, as they can provide feedback that cannot be obtained in a real patient. They provide information about internal organ deformation that can significantly enhance palpation training by giving medical trainees visual insight based on the pressure they apply for palpation. This can be achieved by using computational models of abdomen mechanics. However, such models are computationally expensive, and thus unable to provide real-time predictions. In this work, we proposed an innovative surrogate model of abdomen mechanics by using machine learning (ML) and finite element (FE) modelling to virtually render internal tissue deformation in real time. We first developed a new high-fidelity FE model of the abdomen mechanics from computerized tomography (CT) images. We performed palpation simulations to produce a large database of stress distribution on the liver edge, an area of interest in most examinations. We then used artificial neural networks (ANNs) to develop the surrogate model and demonstrated its application in an experimental palpation platform. Our FE simulations took 1.5 h to predict stress distribution for each palpation while this only took a fraction of a second for the surrogate model. Our results show that our artificial neural network (ANN) surrogate has an accuracy of 92.6%. We also showed that the surrogate model is able to use the experimental input of palpation location and force to provide real-time projections onto the robotics platform. This enhanced robotics platform has the potential to be used as a training simulator for trainees to hone their palpation skills.

Indexed as

abdominal tissue simulatorcomputational modellingfinite element modellinghuman–machine interactionmedical training

Identifiers

PMID36421088
PMCPMC9687124

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.