Comparison of Osseointegration of Dental Implants Placed in Rabbit Tibia Using Two Dental Laser and Implant Handpiece Systems.

Jin-Han Park, Keunbada Son, Young-Tak Son, Yong-Gun Kim, Jo-Young Suh, Kyu-Bok Lee, Jae-Mok Lee

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Dental Restorations.Bioengineering (Basel, Switzerland) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Jin-Han ParkDepartment of Periodontology, School of Dentistry, Kyungpook National University, Daegu 41566, Korea.ORCID 0000-0001-7543-9147
Keunbada SonAdvanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu 41566, Korea.ORCID 0000-0002-3177-8005
Young-Tak SonAdvanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu 41566, Korea.ORCID 0000-0001-8893-5369
Yong-Gun KimDepartment of Periodontology, School of Dentistry, Kyungpook National University, Daegu 41566, Korea.ORCID 0000-0002-2793-7667
Jo-Young SuhDepartment of Periodontology, School of Dentistry, Kyungpook National University, Daegu 41566, Korea.
Kyu-Bok LeeAdvanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu 41566, Korea.ORCID 0000-0002-1838-7229
Jae-Mok LeeDepartment of Periodontology, School of Dentistry, Kyungpook National University, Daegu 41566, Korea.
Kyungpook National University · KR

Funding

Ministry of Trade, Industry, and Energy (MOTIE) and the Korea Institute for Advancement of Technology (KIAT) through the National Innovation Cluster R&D program P0015338
6 · The paper itself

Abstract

The present study aimed to confirm the usefulness of a multi-laser handpiece system currently under development. Implants were placed in the tibia of rabbits using a conventional separate laser-implant handpiece system (control group; SurgicPro+; NSK, Kanuma, Japan and Epic 10; Biolase, Irvine, CA, USA) and a multi-laser handpiece system (experimental group; BLP 10; Saeshin, Daegu, Korea). Implants were placed in left and right tibias of five rabbits using a conventional laser-implant handpiece system and a multi-laser handpiece system (N = 5 per group). Subsequently, micro-computed tomography (micro-CT; bone-to-implant contact evaluation), implant stability quotient (ISQ) measurement, and histological evaluations were performed to confirm the implant placement results. The independent t-test and the paired t-test were used to compare the ISQ values and the results of the two implant-laser handpiece groups (α = 0.05), respectively. No statistically significant difference in micro-CT, ISQ, and histological evaluations was observed between implant placement by the two systems (p > 0.05) except implant initial stability. The use of the multi-laser handpiece system is expected to produce the same results as a conventional separate laser-implant handpiece system with the higher implant initial stability. Additionally, it will potentially make the clinical environment more pleasant and will provide convenience for the clinicians.

Indexed as

dental implantimplant stabilitylaserosseointegration

Identifiers

PMID36421082
PMCPMC9687135
OpenAlexW4309001820

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.