Evidence map›Paper›PMID 36420046›Full record

ArticleCureus2022

Variability, Validity and Operator Reliability of Three Ultrasound Systems for Measuring Tissue Stiffness: A Phantom Study.

Hafsa Javed, Samson O Oyibo, Abdulrahman M Alfuraih

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Hafsa JavedGeneral Medicine, Peterborough City Hospital, Peterborough, GBR.
Samson O OyiboEndocrinology, Peterborough City Hospital, Peterborough, GBR.
Abdulrahman M AlfuraihRadiology, Prince Sattam Bin Abdulaziz University, Al-Kharj, SAU.
Prince Sattam Bin Abdulaziz University · SAPeterborough City Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Ultrasound elastography is a method of measuring soft tissue stiffness to detect the presence of pathology. There are several ultrasound elastography devices on the market. The aim of this study was twofold. Firstly, to determine the validity of three different ultrasound systems used to measure tissue stiffness. Secondly, to determine the operator reliability and repeatability when using these three systems. Materials and methods Two observers undertook multiple stiffness measurements from a phantom model using three different ultrasound systems; the LOGIQ E9, the Aixplorer, and the Acuson S2000. The phantom model had four cylindrical-shaped inclusions (Type 1-4) of increasing stiffness values and diameter embedded within. The background phantom stiffness was fixed. The mean, standard deviation, and coefficient of variation (CV) were calculated from measured stiffness readings per diameter per inclusion. Intra-observer variability was assessed. The validity of the measured stiffness value was assessed by calculating the difference between the measured elasticities and actual phantom elasticities. Bland-Altman plots with limits of agreement were used to display the inter-observer agreement. The intraclass correlation coefficients (ICC) were used to measure intra-observer, inter-observer, and inter-system reliability. Results Each observer undertook 1020 measurements. All three systems generally underestimated the stiffness values for the inclusions; the higher the actual stiffness value, the more significant the underestimation. The percentage difference between measured stiffness and actual stiffness varied from -79.1% to 12.7%. The intra-observer variability was generally less than 5% for observers using the LOGIQ E9 and the Aixplorer systems but more than 10% over the stiffer inclusions (Types 3 and 4) for the Acuson system. There was 'almost perfect' intra-observer reliability and repeatability for both the LOGIQ E9 and the Aixplorer systems; this was 'moderate' for the Acuson system over specific inclusions. For all systems, there was 'almost perfect' inter-observer reliability and repeatability between Observer A and Observer B. The inter-system reliability and repeatability were 'almost perfect' between the LOGIQ E9 system and the Aixplorer system but 'poor' and 'moderate' when the Acuson system was matched with the LOGIQ E9 system and the Aixplorer system, respectively. Conclusion This study has demonstrated that the Acuson, LOGIQ E9, and Aixplorer ultrasound systems have low variability, high reproducibility, and good intra-observer and inter-observer reliability when used to measure tissue stiffness. However, they all underestimated the stiffness values during this in vitro study. This study also revealed that not all ultrasound systems are comparable when measuring tissue stiffness, with some having better inter-system reliability than others. Ongoing standardization of technology is required at the manufacturer level.

Indexed as

phantomreliabilityshear wave elastographytissue stiffnessvalidity

Identifiers

PMID36420046
PMCPMC9678015
OpenAlexW4309779186

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.