ArticleLight, science & applications2022
Hybrid magnetic resonance and optoacoustic tomography (MROT) for preclinical neuroimaging.
Article in Light, science & applications, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 26 citations in OpenAlex.
- Optoacoustic brain imaging: A systematic review and field mapping.Photoacoustics · 2026Article
- In-bore MRI-compatible transrectal ultrasound and photoacoustic imaging.Photoacoustics · 2025Article
- Decoding paradoxical BOLD responses to transcranial ultrasound stimulation with concurrent optoacoustic magnetic resonance imaging.Science advances · 2025Article
- Non-invasive large-scale imaging of concurrent neuronal, astrocytic, and hemodynamic activity with hybrid multiplexed fluorescence and magnetic resonance imaging (HyFMRI).Light, science & applications · 2025Article
- Concurrent optoacoustic tomography and magnetic resonance imaging of resting-state functional connectivity in the mouse brain.Nature communications · 2024Article
- Review on Photoacoustic Monitoring after Drug Delivery: From Label-Free Biomarkers to Pharmacokinetics Agents.Pharmaceutics · 2024Review
- Multimodal optoacoustic imaging: methods and contrast materials.Chemical Society reviews · 2024Review
- Photoacoustic Tomography with Temporal Encoding Reconstruction (PATTERN) for cross-modal individual analysis of the whole brain.Nature communications · 2024Article
- Shedding light on ultrasound in action: Optical and optoacoustic monitoring of ultrasound brain interventions.Advanced drug delivery reviews · 2024Review
- Deep tissue photoacoustic imaging with light and sound.Npj imaging · 2024Review
- Volumetric registration framework for multimodal functional magnetic resonance and optoacoustic tomography of the rodent brain.Photoacoustics · 2023Article
- Monitoring mouse brain perfusion with hybrid magnetic resonance optoacoustic tomography.Biomedical optics express · 2023Article
- Automatic analysis of skull thickness, scalp-to-cortex distance and association with age and sex in cognitively normal elderly.bioRxiv : the preprint server for biology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
Multi-modal imaging is essential for advancing our understanding of brain function and unraveling pathophysiological processes underlying neurological and psychiatric disorders. Magnetic resonance (MR) and optoacoustic (OA) imaging have been shown to provide highly complementary contrasts and capabilities for preclinical neuroimaging. True integration between these modalities can thus offer unprecedented capabilities for studying the rodent brain in action. We report on a hybrid magnetic resonance and optoacoustic tomography (MROT) system for concurrent noninvasive structural and functional imaging of the mouse brain. Volumetric OA tomography was designed as an insert into a high-field MR scanner by integrating a customized MR-compatible spherical transducer array, an illumination module, and a dedicated radiofrequency coil. A tailored data processing pipeline has been developed to mitigate signal crosstalk and accurately register image volumes acquired with T1-weighted, angiography, and blood oxygenation level-dependent (BOLD) sequences onto the corresponding vascular and oxygenation data recorded with the OA modality. We demonstrate the concurrent acquisition of dual-mode anatomical and angiographic brain images with the scanner, as well as real-time functional readings of multiple hemodynamic parameters from animals subjected to oxygenation stress. Our approach combines the functional and molecular imaging advantages of OA with the superb soft-tissue contrast of MR, further providing an excellent platform for cross-validation of functional readings by the two modalities.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.