Evidence map›Paper›PMID 36418439›Full record

ArticleScientific reports2022

Confocal laser endomicroscope with distal MEMS scanner for real-time histopathology.

Miki Lee, Gaoming Li, Haijun Li, Xiyu Duan, Mayur B Birla, Tse-Shao Chang, Danielle K Turgeon, Kenn R Oldham, Thomas D Wang

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Compact, scan-pattern-switchable 2D piezoelectric MEMS mirror with 1D addressable scanning.Journal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems · 2026
    Article
  5. In Vivo Microendoscopy in the Near-Infrared II Window.Small (Weinheim an der Bergstrasse, Germany) · 2026
    Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Confocal laser endomicroscopy for gastric neoplasm.World journal of gastrointestinal endoscopy · 2024
    Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Miki Lee *Department of Internal Medicine, University of Michigan, Ann Arbor, 48109, USA.
Gaoming Li *Department of Internal Medicine, University of Michigan, Ann Arbor, 48109, USA.
Haijun LiDepartment of Internal Medicine, University of Michigan, Ann Arbor, 48109, USA.
Xiyu DuanDepartment of Internal Medicine, University of Michigan, Ann Arbor, 48109, USA.
Mayur B BirlaDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, 48109, USA.
Tse-Shao ChangDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, 48109, USA.
Danielle K TurgeonDepartment of Internal Medicine, University of Michigan, Ann Arbor, 48109, USA.
Kenn R OldhamDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, 48109, USA.
Thomas D WangDepartment of Internal Medicine, University of Michigan, Ann Arbor, 48109, USA. thomaswa@umich.edu.
University of Michigan–Ann Arbor · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Confocal laser endomicroscopy is an emerging methodology to perform real time optical biopsy. Fluorescence images with histology-like quality can be collected instantaneously from the epithelium of hollow organs. Currently, scanning is performed at the proximal end of probe-based instruments used routinely in the clinic, and flexibility to control the focus is limited. We demonstrate use of a parametric resonance scanner packaged in the distal end of the endomicroscope to perform high speed lateral deflections. An aperture was etched in the center of the reflector to fold the optical path. This design reduced the dimensions of the instrument to 2.4 mm diameter and 10 mm length, allowing for forward passage through the working channel of a standard medical endoscope. A compact lens assembly provides lateral and axial resolution of 1.1 and 13.6 μm, respectively. A working distance of 0 μm and field-of-view of 250 μm × 250 μm was achieved at frame rates up to 20 Hz. Excitation at 488 nm was delivered to excite fluorescein, an FDA-approved dye, to generate high tissue contrast. The endomicroscope was reprocessed using a clinically-approved sterilization method for 18 cycles without failure. Fluorescence images were collected during routine colonoscopy from normal colonic mucosa, tubular adenomas, hyperplastic polyps, ulcerative colitis, and Crohn's colitis. Individual cells, including colonocytes, goblet cells, and inflammatory cells, could be identified. Mucosal features, such as crypt structures, crypt lumens, and lamina propria, could be distinguished. This instrument has potential to be used as an accessory during routine medical endoscopy.

Indexed as

Colitis, UlcerativeLensesMicro-Electrical-Mechanical SystemsHistological TechniquesHumansLasers

Identifiers

PMID36418439
PMCPMC9684518
OpenAlexW4309865469

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.