Evidence map›Paper›PMID 36417026›Full record

Trial reportJournal of digital imaging2023

Deep Learning-based Non-rigid Image Registration for High-dose Rate Brachytherapy in Inter-fraction Cervical Cancer.

Mohammad Salehi, Alireza Vafaei Sadr, Seied Rabi Mahdavi, Hossein Arabi, Isaac Shiri, Reza Reiazi

Open access · hybridFull text readRandomized Controlled Trial
In one paragraph

Trial report in Journal of digital imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
4.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Systematic review of artificial intelligence in brachytherapy.Journal of contemporary brachytherapy · 2026
    Review
  4. Article
  5. Review
  6. A review of artificial intelligence in brachytherapy.Journal of applied clinical medical physics · 2025
    Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 4 countries.

Mohammad SalehiDepartment of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
Alireza Vafaei SadrDepartment of Theoretical Physics and Center for Astroparticle Physics, University of Geneva, Geneva, Switzerland.
Seied Rabi MahdaviDepartment of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
Hossein ArabiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva 4, Switzerland.
Isaac ShiriDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva 4, Switzerland. Isaac.shirilord@unige.ch.ORCID 0000-0002-5735-0736
Reza ReiaziDepartment of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran. rreiazi@mdanderson.org.
Iran University of Medical Sciences · IRUniversity of Geneva · CHThe University of Texas MD Anderson Cancer Center · USUniversity Hospital of Geneva · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, an inter-fraction organ deformation simulation framework for the locally advanced cervical cancer (LACC), which considers the anatomical flexibility, rigidity, and motion within an image deformation, was proposed. Data included 57 CT scans (7202 2D slices) of patients with LACC randomly divided into the train (n = 42) and test (n = 15) datasets. In addition to CT images and the corresponding RT structure (bladder, cervix, and rectum), the bone was segmented, and the coaches were eliminated. The correlated stochastic field was simulated using the same size as the target image (used for deformation) to produce the general random deformation. The deformation field was optimized to have a maximum amplitude in the rectum region, a moderate amplitude in the bladder region, and an amplitude as minimum as possible within bony structures. The DIRNet is a convolutional neural network that consists of convolutional regressors, spatial transformation, as well as resampling blocks. It was implemented by different parameters. Mean Dice indices of 0.89 ± 0.02, 0.96 ± 0.01, and 0.93 ± 0.02 were obtained for the cervix, bladder, and rectum (defined as at-risk organs), respectively. Furthermore, a mean average symmetric surface distance of 1.61 ± 0.46 mm for the cervix, 1.17 ± 0.15 mm for the bladder, and 1.06 ± 0.42 mm for the rectum were achieved. In addition, a mean Jaccard of 0.86 ± 0.04 for the cervix, 0.93 ± 0.01 for the bladder, and 0.88 ± 0.04 for the rectum were observed on the test dataset (15 subjects). Deep learning-based non-rigid image registration is, therefore, proposed for the high-dose-rate brachytherapy in inter-fraction cervical cancer since it outperformed conventional algorithms.

Indexed as

BrachytherapyDeep LearningUterine Cervical NeoplasmsFemaleHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRectumBrachytherapyConvolutional neural networksCTDeformable image registrationLocally advanced cervix cancer

Identifiers

PMID36417026
PMCPMC10039214
OpenAlexW4309837635

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read4
table measurements read1
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.