Evidence map›Paper›PMID 36417013›Full record

ArticleMagma (New York, N.Y.)2023

Concept for gradient-free MRI on twin natural slices.

Gordon E Sarty

Abstract read
PubMed Publisher
In one paragraph

Article in Magma (New York, N.Y.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Image Encoding With Blipped Gradients in an Echo Train.Magnetic resonance in medicine · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Gordon E SartyDivision of Biomedical Engineering and the quanTA Centre, University of Saskatchewan, Saskatoon, Saskatchewan, Canada. gordon.sarty@usask.ca.ORCID http://orcid.org/0000-0001-5516-7869

Funding

Canadian Space Agency 15FASTA01Natural Sciences and Engineering Research Council of Canada RGPIN-2017-03740
6 · The paper itself

Abstract

objectiveThe design of an MRI for use in space requires that the hardware be kept to an absolute minimum in terms of mass, complexity, and power. In addition, NASA requirements are that the external stray field needs to be less than 3.2 Gauss, 7 cm from the MRI enclosure. THEORY: RF encoding designs with Halbach magnets offer the best chance of meeting those requirements. Spatially non-uniform magnetic fields with foliations of isomagnetic surfaces, or natural slices, may be used to provide slice selection, and to reduce further the hardware complexity, for TRansmit Array Spatial Encoding (TRASE) Magnetic Resonance Imaging (MRI) or potentially for other radio frequency (RF) encoding methods. The design of such non-uniform magnetic fields in a Halbach configuration with built-in axial gradients leads to pairs of isomagnetic surfaces centered on either side of a central maximum field strength slice. If TRASE images from slices other than the central isomagnetic surface are desired, then the Nuclear Magnetic Resonance (NMR) signals originating from the twin natural slices must be separated during image reconstruction. Here, a design for simultaneously imaging on twin slices in such an inhomogeneous magnetic field using multiple receiver coils with spatially varying RF profiles is described mathematically and numerical simulation examples are given. DESIGN APPROACH: To achieve RF encoding on the natural slices, at least three TRASE transmit coils are required. Here a solution with twisted solenoid coils is given. To achieve the twin slice separation at least two receive coils are required. Here a solution with two solenoids is given. DISCUSSION: The MRI design presented here uses a combination of RF encoding (TRASE), a spatial encoding magnetic field (SEM, pairs of natural slices) and receive coil spatial profiles to encode enough information into the NMR signal for image slice reconstruction. The design presented here enables using Halbach magnets with a built-in axial gradient to be used for MRI.

conclusionThe result is a new gradient-free TRASE MRI design capable of imaging pairs of electronically selectable axial slices.

Indexed as

Image Processing, Computer-AssistedMagnetic Resonance ImagingComputer SimulationEquipment DesignMagnetic Resonance SpectroscopyPhantoms, ImagingRadio WavesHalbach magnetsImage reconstructionLow-field MRITRASE

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.