Evidence map›Paper›PMID 36416296›Full record

ArticleJournal of biomechanical engineering2023

The Accelerated Transcatheter Heart Valve Testing Environment: Loading, Motion, and Fluid Dynamics.

Sailahari V Ponnaluri, Michael S Sacks, Keefe B Manning

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Bioinspired functional materials for biomedical applications.Frontiers in bioengineering and biotechnology · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Sailahari V PonnaluriDepartment of Biomedical Engineering, The Pennsylvania State University, 122 Chemical and Biomedical Engineering Building, University Park, PA 16802.
Michael S SacksJames T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering Sciences, University of Texas, Austin, TX 78712; Department of Biomedical Engineering, University of Texas, Austin, TX 78712.
Keefe B ManningDepartment of Biomedical Engineering, The Pennsylvania State University, 122 Chemical and Biomedical Engineering Building, University Park, PA 16802; Department of Surgery, Penn State Hershey Medical Center, Hershey, PA 17033.
Pennsylvania State University · USThe University of Texas at Austin · US

Funding

Novel Simulation Technologies for BHV Long-Term DurabilityR01HL129077 · NHLBI · UNIVERSITY OF TEXAS AT AUSTIN · PI HUGHES, THOMAS J., MANNING, KEEFE B · 2016 to 2019
$2.1M
NHLBI NIH HHS R01 HL129077
6 · The paper itself

Abstract

Transcatheter aortic valve replacements (TAVRs) are an increasingly common treatment for aortic valve disease due to their minimally invasive delivery. As TAVR designs require thinner leaflets to facilitate catheter-based delivery, they experience greater leaflet operational stresses and potentially greater durability issues than conventional surgical valves. Yet, our understanding of TAVR durability remains largely unexplored. Currently, preclinical TAVR durability is evaluated within an ISO:5840 compliant accelerated wear tester (AWT) up to a required 200 × 106 cycles, corresponding to approximately five years in vivo. While AWTs use high cycle frequencies (10-20 Hz) to achieve realistic timeframes, the resulting valve loading behaviors and fluid dynamics are not representative of the in vivo environment and thus may not accurately predict failure mechanisms. Despite the importance of fatigue and failure predictions for replacement heart valves, surprisingly, little quantitative information exists on the dynamic AWT environment. To better understand this environment, we examined frequency and diastolic period effects for the first time using high-speed enface imaging and particle image velocimetry to quantify valve motion and flow, respectively, using a Durapulse™ AWT at frequencies of 10, 15, and 20 Hz. Regardless of operating condition, no waveform achieved a physiologically relevant transvalvular loading pressure, despite having an ISO compliant geometric orifice area (GOA) and waveform. General fluid mechanics were consistent with in vivo but the AWT geometry developed secondary flow structures, which could impact mechanical loading. Therefore, the nonphysiologic loading and variability induced by changes in operating condition must be carefully regulated to ensure physiologically relevant fatigue.

Indexed as

Heart ValvesHydrodynamicsaccelerated wear testerfluid dynamicstranscatheter aortic valveturbulence

Identifiers

PMID36416296
PMCPMC9791666
OpenAlexW4309765373

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.