ArticleJournal of diabetes science and technology2024
Continuous Glucose Monitoring in Pediatric Diabetic Ketoacidosis.
Article in Journal of diabetes science and technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 12 citations in OpenAlex.
- Continuous Glucose Monitoring and Hypoglycaemia Risk During Paediatric DKA Treatment in the PICU: A Retrospective Cohort Study.Diabetes, obesity & metabolism · 2026Article
- The Impact of Interfering Substances on Continuous Glucose Monitors: Part 4: Continuous Glucose Monitoring Interferents: In Vivo Performance, Clinical Implications and Future Standardization.Journal of diabetes science and technology · 2026Review
- About potential value and limitations of continuous glucose monitoring in DKA.European journal of pediatrics · 2025Article
- Feasibility of continuous glucose monitoring in children with diabetic ketoacidosis: an exploratory observational study.European journal of pediatrics · 2025Observational
- Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review.Intensive care medicine · 2024Article
- Expanding the horizon of continuous glucose monitoring into the future of pediatric medicine.Pediatric research · 2024Review
- Accuracy of a Real-Time Continuous Glucose Monitor in Pediatric Diabetic Ketoacidosis Admissions.Diabetes technology & therapeutics · 2024Article
- Accuracy of a Continuous Glucose Monitor During Pediatric Type 1 Diabetes Inpatient Admissions.Diabetes technology & therapeutics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundUse of real-time continuous glucose monitoring (rtCGM) in ambulatory settings improves overall glycemic control and reduces the incidence of diabetic ketoacidosis (DKA) in adults and children/adolescents with type 1 diabetes (T1D). However, the use of rtCGM in children with DKA has not been well studied.
methodThis prospective, single-arm, single-center study assessed the accuracy, reliability, and feasibility of a commercially available rtCGM device compared with point-of-care (POC) capillary and serum glucose values in pediatric patients admitted to the pediatric intensive care unit for DKA. The primary outcome was the accuracy of rtCGM glucose values compared with POC capillary and serum glucose values during standard treatment of DKA as assessed by Clarke Error Grid (CEG) analysis. Secondary outcomes were assessment of the relationship between rtCGM readings and degree of acidosis and mean length of hospital stay (LOS).
resultsData from 35 hospitalized children (mean ± SD age, 11.9 ± 4.1 years) with DKA were included in our analysis. Five hundred twenty-four time-matched glucose values between serum glucose and rtCGM and 91 time-matched glucose values between POC capillary glucose and rtCGM were obtained. The effect of acidosis on accuracy CEG analysis showed 95.4% of the 524 matched CGM/POC pairs and 95.6% of the 91 matched CGM/serum glucose pairs in the clinically acceptable A + B zones. The average LOS was 1.32 ± 0.73 days. Serum bicarbonate level did not appear to affect the accuracy of rtCGM in the setting of DKA.
conclusionsContinuous glucose monitoring use in inpatient pediatric DKA treatment was found to be feasible and reliable.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials