Evidence map›Paper›PMID 36412877›Full record

ArticleJournal of functional biomaterials2022

Hemodynamic Analysis of the Geometric Features of Side Holes Based on GDK Catheter.

Yang Yang, Yijing Li, Chen Liu, Jingyuan Zhou, Tao Li, Yan Xiong, Ling Zhang

Open access · goldAbstract read
In one paragraph

Article in Journal of functional biomaterials, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. NiagaraFrontiers in bioengineering and biotechnology · 2025
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Yang YangCollege of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Yijing LiCollege of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Chen LiuDepartment of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu 610041, China.
Jingyuan ZhouDepartment of Applied Mechanics, Sichuan University, Chengdu 610065, China.
Tao LiCollege of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Yan XiongCollege of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Ling ZhangDepartment of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu 610041, China.ORCID 0000-0003-1155-4802
Sichuan University · CN

Funding

Sichuan Provincial Science and Technology Department Project 2020YFG0105
6 · The paper itself

Abstract

Hemodialysis is an important means to maintain life in patients with end-stage renal disease (ESRD). Approximately 76.8% of patients who begin hemodialysis do so through catheters, which play vital roles in the delivery of hemodialysis to patients. During the past decade, the materials, structures, and surface-coating technologies of catheters have constantly been evolving to ameliorate catheter-related problems, such as recirculation, thrombosis, catheter-related infections, and malfunction. In this study, based on the commercial GDK catheter, six catheter models (GDK, GDK1, GDK2, GDK3, GDK4, and GDK5) with different lumen diameters and different geometric features of side holes were established, and computational flow dynamics (CFD) were used to measure flow rate, shear stress, residence time (RT), and platelet lysis index (PLI). These six catheters were then printed with polycarbonate PC using 3D printing technology to verify recirculation rates. The results indicated that: (1) the catheter with a 5.5 mm outer diameter had the smallest average shear stress in the arterial lumen and the smallest proportion of areas with shear stress > 10 pa. With increasing catheter diameter, the shear stress in the tip volume became lower, the average RT increased, and the PLI decreased due to larger changes in shear stress; (2) the catheters with oval-shaped side holes had smaller shear stress levels than those with circular-shaped holes, indicating that the oval design was more effective; (3) the catheter with parallel dual side holes had uniformly distributed flow around side holes and exhibited lower recirculation rates in both forward and reverse connections, while linear multi-side holes had higher shear stress levels due to the large differences in flow around side holes. The selection of the material and the optimization of the side holes of catheters have significant impacts on hemodynamic performances and reduce the probability of thrombosis, thus improving the efficiency of dialysis. This study would provide some guidance for optimizing catheter structures and help toward the commercialization of more efficient HD catheters.

Indexed as

cathetergeometric featureshemodynamicshear stressside holes

Identifiers

PMID36412877
PMCPMC9680405
OpenAlexW4309004593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.