Evidence map›Paper›PMID 36411869›Full record

ArticleStructural dynamics (Melville, N.Y.)2022

Expected resolution limits of x-ray free-electron laser single-particle imaging for realistic source and detector properties.

Juncheng E, Y Kim, J Bielecki, M Sikorski, R de Wijn, C Fortmann-Grote, J Sztuk-Dambietz, J C P Koliyadu, R Letrun, H J Kirkwood and 4 more

Abstract read
In one paragraph

Article in Structural dynamics (Melville, N.Y.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. In-Cell Dynamics: The Next Focus of All-Atom Simulations.The journal of physical chemistry. B · 2023
    Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Juncheng EEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID https://orcid.org/0000-0001-6061-5734
Y KimEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
J BieleckiEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID https://orcid.org/0000-0002-3012-603X
M SikorskiEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
R de WijnEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
C Fortmann-Grote
J Sztuk-DambietzEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
J C P KoliyaduEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID https://orcid.org/0000-0002-0245-3842
R LetrunEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
H J KirkwoodEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID https://orcid.org/0000-0001-6792-3844
T SatoEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
R BeanEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
A P Mancuso
C KimEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID https://orcid.org/0000-0003-4559-7982

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The unprecedented intensity of x-ray free-electron laser sources has enabled single-particle x-ray diffraction imaging (SPI) of various biological specimens in both two-dimensional projection and three dimensions (3D). The potential of studying protein dynamics in their native conditions, without crystallization or chemical staining, has encouraged researchers to aim for increasingly higher resolutions with this technique. The currently achievable resolution of SPI is limited to the sub-10 nanometer range, mainly due to background effects, such as instrumental noise and parasitic scattering from the carrier gas used for sample delivery. Recent theoretical studies have quantified the effects of x-ray pulse parameters, as well as the required number of diffraction patterns to achieve a certain resolution, in a 3D reconstruction, although the effects of detector noise and the random particle orientation in each diffraction snapshot were not taken into account. In this work, we show these shortcomings and address limitations on achievable image resolution imposed by the adaptive gain integrating pixel detector noise.

Identifiers

PMID36411869
PMCPMC9675053

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.