ArticleScientific reports2022
Surface characterization of an ultra-soft contact lens material using an atomic force microscopy nanoindentation method.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 17 citations in OpenAlex.
- Traceable stiffness calibration of colloidal AFM probes for biomechanical measurements.Scientific reports · 2026Article
- Analysis of the Hertz Contact Model for Evaluating Mechanical Properties of Polymers Using the Finite Element Method.Polymers · 2025Article
- Modeling and Validation of Oocyte Mechanical Behavior Using AFM Measurement and Multiphysics Simulation.Sensors (Basel, Switzerland) · 2025Article
- Comparison of Asian dust adhesion on the surface of different reusable silicone hydrogel contact lenses.International ophthalmology · 2025Article
- Article
- High-throughput design of a light and strong refractory eutectic medium entropy alloy with outstanding He-ion irradiation resistance.Science advances · 2025Article
- Comparison of Non-Water Proof Mascara Adhesion on the Surface of Different Two-week Frequent Replacement Silicone Hydrogel Contact Lenses.Clinical optometry · 2025Article
- Fluid confinement within a branched polymer structure enhances tribological performance of a poly(2-methacryloyloxyethyl phosphorylcholine)-surface-modified contact lens.Royal Society open science · 2024Article
- Soft Contact Lens Engraving Characterization by Wavefront Holoscopy.Sensors (Basel, Switzerland) · 2024Article
- Biomimetic-Engineered Silicone Hydrogel Contact Lens Materials.ACS applied bio materials · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
As new ultra-soft materials are being developed for medical devices and biomedical applications, the comprehensive characterization of their physical and mechanical properties is both critical and challenging. To characterize the very low surface modulus of the novel biomimetic lehfilcon A silicone hydrogel contact lens coated with a layer of a branched polymer brush structure, an improved atomic force microscopy (AFM) nanoindentation method has been applied. This technique allows for precise contact-point determination without the effects of viscous squeeze-out upon approaching the branched polymer. Additionally, it allows individual brush elements to be mechanically characterized in the absence of poroelastic effects. This was accomplished by selecting an AFM probe with a design (tip size, geometry, and spring constant) that was especially suited to measuring the properties of soft materials and biological samples. The enhanced sensitivity and accuracy of this method allows for the precise measurement of the very soft lehfilcon A material, which has an extremely low elastic modulus in the surface region (as low as 2 kPa) and extremely high elasticity (nearly 100%) in an aqueous environment. The surface-characterization results not only reveal the ultra-soft nature of the lehfilcon A lens surface but also demonstrate that the elastic modulus exhibits a 30 kPa/200 nm gradient with depth due to the disparity between the modulus of the branched polymer brushes and the SiHy substrate. This surface-characterization methodology may be applied to other ultra-soft materials and medical devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.