Evidence map›Paper›PMID 36411083›Full record

ArticleACS sensors2022

Rapid Measurement of Lactate in the Exhaled Breath Condensate: Biosensor Optimization and In-Human Proof of Concept.

Shulin Zhang, Yu-Chih Chen, Alaa Riezk, Damien Ming, Lidiia Tsvik, Leander Sützl, Alison Holmes, Danny O'Hare

Abstract read
In one paragraph

Article in ACS sensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Exhaled Breath Analysis: From Laboratory Test to Wearable Sensing.IEEE reviews in biomedical engineering · 2025
    Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shulin ZhangDepartment of Bioengineering, Imperial College London, LondonSW7 2AZ, U.K.ORCID 0000-0003-4011-9164
Yu-Chih ChenDepartment of Bioengineering, Imperial College London, LondonSW7 2AZ, U.K.
Alaa RiezkFaculty of Medicine, Department of Infectious Disease, Centre for Antimicrobial Optimisation, Imperial College London, LondonSW7 2AZ, U.K.
Damien MingFaculty of Medicine, Department of Infectious Disease, Centre for Antimicrobial Optimisation, Imperial College London, LondonSW7 2AZ, U.K.
Lidiia TsvikLaboratory of Food Biotechnology, Department of Food Science and Technology, BOKU-University of Natural Resources and Life Sciences Vienna, Muthgasse 11, WienA-1190, Austria.ORCID 0000-0002-0339-3378
Leander SützlLaboratory of Food Biotechnology, Department of Food Science and Technology, BOKU-University of Natural Resources and Life Sciences Vienna, Muthgasse 11, WienA-1190, Austria.
Alison HolmesFaculty of Medicine, Department of Infectious Disease, Centre for Antimicrobial Optimisation, Imperial College London, LondonSW7 2AZ, U.K.
Danny O'HareDepartment of Bioengineering, Imperial College London, LondonSW7 2AZ, U.K.ORCID 0000-0002-0820-2999

Funding

Department of Health
6 · The paper itself

Abstract

Lactate concentration is of increasing interest as a diagnostic for sepsis, septic shock, and trauma. Compared with the traditional blood sample media, the exhaled breath condensate (EBC) has the advantages of non-invasiveness and higher user acceptance. An amperometric biosensor was developed and its application in EBC lactate detection was investigated in this paper. The sensor was modified with PEDOT:PSS-PB, and two different lactate oxidases (LODs). A rotating disk electrode and Koutecky-Levich analysis were applied for the kinetics analysis and gel optimization. The optimized gel formulation was then tested on disposable screen-printed sensors. The disposable sensors exhibited good performance and presented a high stability for both LOD modifications. Finally, human EBC analysis was conducted from a healthy subject at rest and after 30 min of intense aerobic cycling exercise. The sensor coulometric measurements showed good agreement with fluorometric and triple quadrupole liquid chromatography mass spectrometry reference methods. The EBC lactate concentration increased from 22.5 μM (at rest) to 28.0 μM (after 30 min of cycling) and dropped back to 5.3 μM after 60 min of rest.

Indexed as

Biosensing TechniquesLactic AcidBreath TestsHumansMass SpectrometryLactic Acidclinical diagnosticsexhaled breath condensatelactate biosensorlactate oxidasenon-invasive detectionPrussian blue

Identifiers

PMID36411083
PMCPMC9791687

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.