Trial reportInternational biomechanics2022
Biomechanical testing of different fixation techniques for intraoperative proximal femur fractures: a technical note.
Trial report in International biomechanics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 5 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intraoperative proximal femoral fractures (IPFF) represent a rare but challenging complication of total hip arthroplasties. They usually occur as a longitudinal split. This pilot trial aimed to compare the biomechanical primary stability of different fixation techniques for IPFF. Standardised longitudinal medial split fractures of the proximal femur (type II, Modified Mallory Classification) were created in artificial osteoporotic and non-osteoporotic composite femora after implantation of a cementless femoral stem. Five different fixation techniques were compared: cerclage band, cerclage wiring with one or two wires, and lag screw fixation with one or two lag screws. A quasi-static loading protocol was applied and failure loads were evaluated. The observed median failure loads were 4192N (3982N - 5189N) for one cerclage band, 4450N (3577N - 4927N) for one cerclage wire, 5016N (4175N - 5685N) for two cerclage wires, 6085N (5000N - 8907N) for one lag screw, and 4774N (4509N - 8502N) for two lag screws. Due to the wide range of failure loads within the experimental groups, there were no observable differences between the groups. All fixation techniques provided sufficient primary stability in osteoporotic and non-osteoporotic composite bones. Further cadaveric studies with larger sample sizes may be needed to confirm the results presented here.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.