Geometry design for a fully insertable glucose biosensor with multimodal optical readout.

Jesse Fine, Gerard L Coté, Michael J McShane

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jesse FineTexas A&M University, Department of Biomedical Engineering, College Station, Texas, United States, United States.
Gerard L CotéTexas A&M University, Department of Biomedical Engineering, College Station, Texas, United States, United States.
Michael J McShaneTexas A&M University, Department of Biomedical Engineering, College Station, Texas, United States, United States.

Funding

Minimally-Invasive Metabolite Monitoring Systems for in vitro and in vivo Disease ModelsR01EB024601 · NIBIB · TEXAS ENGINEERING EXPERIMENT STATION · PI MCSHANE, MIKE · 2018 to 2021
$1.3M
NIBIB NIH HHS R01 EB024601
6 · The paper itself

Abstract

Significance: Insertable optical continuous glucose monitors (CGMs) with wearable readers are a strong option for monitoring individuals with diabetes. However, a fully insertable CGM requires a small form factor while still delivering sufficient signal to be read through tissue by an external device. Previous work has suggested that a multimodal repeating unit (barcode) approach may meet these requirements, but the biosensor geometry must be optimized to meet performance criteria. Aim: This work details in silico trials conducted to evaluate the geometry of a fully insertable multimodal optical biosensor with respect to both optical output and species diffusion in vivo. Approach: Monte Carlo modeling is used to evaluate the luminescent output of three presupposed biosensor designs based on size constraints for an injectable and logical placement of the bar code compartments. Specifically, the sensitivity of the luminescent output to displacement of the biosensor in the X and Y directions, overall size of the selected design, and size of an individual repeating unit are analyzed. Further, an experimentally validated multiphysics model is used to evaluate the diffusion and reaction of glucose and oxygen within the biosensor to estimate the occurrence of chemical crosstalk between the assay components. Results: A stacked cylinder multimodal biosensor 4.4 mm in length with repeating units 0.36 mm in length was found to yield a greater luminescent output than the current "barcode" biosensor design. In addition, it was found that a biosensor with enzymatic elements does not significantly deplete glucose locally and thus does not impact the diffusion profile of glucose in adjacent compartments containing nonenzymatic assays. Conclusions: Computational modeling was used to design the geometry of a multimodal, insertable, and optical CGM to ensure that the optical output and chemical diffusion profile are sufficient for this device to function in vivo.

Indexed as

Biosensing TechniquesDiabetes MellitusBlood GlucoseGlucoseHumansLuminescenceBlood GlucoseGlucosebiophotonicsfluorescenceimplanted deviceslifetimephosphorescencespectroscopywearable sensors

Identifiers

PMID36401344
PMCPMC9673816

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.