Evidence map›Paper›PMID 36398261›Full record

ArticleAmerican journal of translational research2022

Design and evaluation of a multimodal balance training system.

Zhan Zhao, Jian-Min Zhu, Hai-Po Cui, Mei-Jun An

Open access · greenAbstract read
In one paragraph

Article in American journal of translational research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Zhan ZhaoShanghai Institute for Minimally Invasive Therapy, University of Shanghai for Science and Technology Shanghai 200093, PR China.
Jian-Min ZhuSchool of Mechanical Engineering, University of Shanghai for Science and Technology Shanghai 200093, PR China.
Hai-Po CuiShanghai Institute for Minimally Invasive Therapy, University of Shanghai for Science and Technology Shanghai 200093, PR China.
Mei-Jun AnShanghai University of Medicine & Health Sciences Shanghai 200120, PR China.
University of Shanghai for Science and Technology · CNShanghai University of Medicine and Health Sciences · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveCurrent balance training systems are designed exclusively for one particular type of training and assessment. Additionally, they comprise monotonous training programs. Therefore, patients in different stages of rehabilitation must use different balance training models from different manufacturers, resulting in high treatment cost. Furthermore, large spaces are required to accommodate the balance training machines, and doctors and physiotherapists have to learn to operate multiple machines. We aimed to design a multimodal balance training and assessment system that can accommodate the assessment and training of static, dynamic, reactive and proactive balance to satisfy individual needs.

methodsThe difficulty associated with combining static, dynamic, reactive and proactive balance training in a single system was to use radial and circumferential driving mechanisms together with a clutch mechanism, whereby circumferential and radial drivers were installed in the base of the system to drive a compound foot plate system with interchangeable springs, in order to adjust stiffness using the clutch. Based on the kinematic equation, the influence of system parameters on the change of the body's center of gravity were evaluated. The parameters included the radial offset of the driving mechanism (

resultsThe difficulties associated with combining static, dynamic, reactive and proactive balance training models in a single system were solved using radial and circumferential driving mechanisms together with a clutch mechanism. The foot plate can swing back and forth within ±20° around the X-axis, swing left and right within ±20° around the Y-axis, swing diagonally within ±20°, swing 360° around the Z-axis, and adjust the height along the Z-axis. Furthermore, the inclination angle

conclusionThe developed balance training system is suitable for patients in different stages of rehabilitation. By providing multiple functionalities, this system can ensure high use rates, reduce costs and save space.

Indexed as

balance assessmentBalance trainingmultiple functional modulesrehabilitation

Identifiers

PMID36398261
PMCPMC9641430
OpenAlexW4309408856

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.