Evidence map›Paper›PMID 36396904›Full record

ArticleHigh blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension2023

Target Blood Pressure Values in Ambulatory Blood Pressure Monitoring.

Katarzyna Lewandowska, Stanisław Wasiliew, Agata Kukfisz, Michał Hofman, Patrycja Woźniak, Artur Radziemski, Łukasz Stryczyński, Dawid Lipski, Andrzej Tykarski, Paweł Uruski

Abstract read
In one paragraph

Article in High blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Katarzyna LewandowskaDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland. katarzyna.piotrowska93@gmail.com.ORCID http://orcid.org/0000-0002-6385-886X
Stanisław WasiliewDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland.
Agata KukfiszDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland.
Michał HofmanDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland.
Patrycja WoźniakDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland.
Artur RadziemskiDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland.
Łukasz StryczyńskiDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland.
Dawid LipskiDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland.
Andrzej TykarskiDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland.
Paweł UruskiDepartment of Hypertensiology, Angiology and Internal Medicine, Poznan University of Medical Sciences, Długa 1/2, 61-848, Poznan, Poland.ORCID http://orcid.org/0000-0002-6798-3043

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introduction2018 ESC/ESH guidelines have recommended 24-h ambulatory blood pressure monitoring to assess hypotensive therapy in many circumstances. Recommended target blood pressure in office blood pressure measurements is between 120/70 and 130/80 mmHg. Such targets for 24-h ambulatory blood pressure monitoring lacks.

aimWe aimed to define target values of blood pressure in 24-h ambulatory blood pressure monitoring in hypertensive patients.

methodsOffice blood pressure measurements and 24-h ambulatory blood pressure monitoring data were collected from 1313 hypertensive patients and sorted following increasing systolic (SBP)/diastolic (DBP) blood pressure in office blood pressure measurements. The corresponding 24-h ambulatory blood pressure monitoring to office blood pressure measurements values were calculated.

resultsValues 130/80 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 113.74/66.95 mmHg; daytime SBP/DBP mean: 135.02/81.78 mmHg and 24-h SBP/DBP mean: 130.24/78.73 mmHg. Values 120/70 mmHg in office blood pressure measurements correspond in 24-h ambulatory blood pressure monitoring: night-time SBP/DBP mean: 109.50/63.43 mmHg; daytime SBP/DBP mean: 131.01/78.47 mmHg and 24-h SBP/DBP mean: 126.36/75.31 mmHg.

conclusionsThe proposed blood pressure target values in 24-h ambulatory blood pressure monitoring complement the therapeutic target indicated in the ESC/ESH recommendations and improves 24-h ambulatory blood pressure monitoring usefulness in clinical practice.

Indexed as

Blood Pressure Monitoring, AmbulatoryHypertensionBlood PressureBlood Pressure DeterminationHumans24-h ambulatory blood pressure monitoringArterial hypertensionBlood pressure monitoringOffice blood pressure monitoring

Identifiers

PMID36396904
PMCPMC9908722

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.