Evidence map›Paper›PMID 36394692›Full record

ArticleSleep & breathing = Schlaf & Atmung2023

Reliability of respiratory event detection with continuous positive airway pressure in moderate to severe obstructive sleep apnea - comparison of polysomnography with a device-based analysis.

Matthias Richter, Maik Schroeder, Ulrike Domanski, Matthias Schwaibold, Georg Nilius

Registry-linked trialOpen access · bronzeAbstract readComparative Study
In one paragraph

Article in Sleep & breathing = Schlaf & Atmung, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04407949 (Untersuchung Der Übereinstimmung Der Ereigniserkennung Von "prismaLine" Geräten Mit Der Polysomnographie), which is not on this map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04407949 nacompletednot on this map

Untersuchung Der Übereinstimmung Der Ereigniserkennung Von "prismaLine" Geräten Mit Der Polysomnographie

TypeinterventionalSponsorInstitut für Pneumologie Hagen Ambrock eVRan2019 to 2020Enrolled70ConditionsSleep Apnea SyndromesArmsCPAP Treatment
3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Matthias RichterKEM | Evang. Kliniken Essen-Mitte gGmbH, Am Deimelsberg 34 a, 45276, Essen, Germany.
Maik SchroederKEM | Evang. Kliniken Essen-Mitte gGmbH, Am Deimelsberg 34 a, 45276, Essen, Germany. m.schroeder@kem-med.com.ORCID 0000-0002-1794-2710
Ulrike DomanskiKEM | Evang. Kliniken Essen-Mitte gGmbH, Am Deimelsberg 34 a, 45276, Essen, Germany.
Matthias SchwaiboldLoewenstein Medical Technology GmbH + Co. KG, Hamburg, Germany.
Georg NiliusKEM | Evang. Kliniken Essen-Mitte gGmbH, Am Deimelsberg 34 a, 45276, Essen, Germany.
Kliniken Essen-Mitte · DELoewenstein Medical Technology (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMonitored polysomnography (PSG) is considered the gold standard technique to diagnose obstructive sleep apnea (OSA) and titrate continuous positive airway pressure (CPAP), the accepted primary treatment method. Currently, the American Academy of Sleep Medicine (AASM) considers automatic PAP therapy initiation at home comparable to laboratory titration and recommends telemonitoring-guided interventions. Advanced CPAP devices evaluate and report the residual apnea-hypopnea index (AHI). However, in order to control the effectiveness of the prescribed therapy outside of a PSG setting, the automatic event detection must provide reliable data.

methodsA CPAP titration was performed in the sleep laboratory by PSG in patients with OSA. The residual event indices detected by the tested device (prismaLine, Loewenstein Medical Technology) were compared to the manually scored PSG indices. Results of the device (AHI

resultsIn 50 patients with OSA, the mean PSG AHI

conclusionThe device-based analysis showed a high correlation in the determination of residual obstructive AHI under therapy. The recorded residual respiratory event indices in combination with the data about leakage and adherence of the studied device provide reliable information for the implementation and follow-up of CPAP therapy in a typical group of patients with OSA. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier: NCT04407949, May 29, 2020, retrospectively registered.

Indexed as

Continuous Positive Airway PressureSleep Apnea, ObstructiveHumansOxygenPolysomnographyReproducibility of ResultsOxygenAHIAutomatic event detectionOSAPSG

Identifiers

PMID36394692
PMCPMC9669528
OpenAlexW4309412446

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.