ArticleAnnals of translational medicine2022
Comparison on the consistency of Mindray and Siemens chemiluminescence analyzers for detecting FT3, FT4 and TSH in patients with hyper- and hypothyroidism.
Article in Annals of translational medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- Performance validation of Abbott Alinity i chemiluminescence analyzer for five thyroid function tests.Practical laboratory medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: To examine the consistency of the Mindray and Siemens full-automatic chemiluminescence analyzers in detecting serum free triiodothyronine (FT3), free thyroxine (FT4) and thyroid stimulating hormone (TSH) in patients with hyper- or hypothyroidism. Methods: Included in this study were 164 new patients with abnormal thyroid function assessed at Nan Fang Hospital of Southern Medical University in 2021: 107 patients with hyperthyroidism and 57 with hypothyroidism. Additional 100 healthy individuals comprised the control group. Consistency of the FT3, FT4 and TSH results from the two systems in the different groups was analyzed by Kappa, linear correlation, regression, Bland-Altman and area under the receiver operating characteristic curve (AUC). Results: Compared with the control group, FT3 and FT4 levels were increased and TSH level was decreased in the hyperthyroid group (both P<0.05), whereas FT3 and FT4 levels were decreased and TSH level was increased in the hypothyroidism group (both P<0.05), suggesting that both test systems could provide references for relevant clinical evaluation. Kappa analysis showed high consistency of the two systems in detecting FT3, FT4 and TSH in both hyper- and hypothyroidism patients (mean Kappa value >0.7). In addition, there was a good linear correlation between the test results of the two systems (R Conclusions: Mindray and Siemens chemiluminescence analyzers are highly consistent in detecting FT3, FT4 and TSH in both hyper- and hypothyroidism patients.