ArticleFrontiers in public health2022
A forced cough sound based pulmonary function assessment method by using machine learning.
Article in Frontiers in public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.
- Cough biomarkers for diagnosis and monitoring of respiratory disease: a systematic review.European respiratory review : an official journal of the European Respiratory Society · 2026Pooled it
- Construction and Validation of an Automatic Segmentation Method for Respiratory Sound Time Labels.The clinical respiratory journal · 2025Article
- Effects of acetylcysteine combined with bronchoalveolar lavage under fiberoptic bronchoscopy on blood oxygenation and inflammation in elderly severe pneumonia patients.American journal of translational research · 2025Article
- The value of cough sound monitoring via an audio-enabled smartwatch for OSA screening in COPD patients: a cross-sectional exploratory study.Frontiers in medicine · 2025Article
- Cough Sounds in Screening and Diagnostics: A Scoping Review.The Laryngoscope · 2024Article
- A noval pulmonary function evaluation method based on ResNet50 + SVR model and cough.Scientific reports · 2023Article
- Research on the Application of Artificial Intelligence in Public Health Management: Leveraging Artificial Intelligence to Improve COVID-19 CT Image Diagnosis.International journal of environmental research and public health · 2023Article
- Intelligent wearable devices with audio collection capabilities to assess chronic obstructive pulmonary disease severity.Digital healthArticle
- Smartwatch-based ventilatory assessment for COPD screening: A diagnostic accuracy study.Digital healthArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Pulmonary function testing (PFT) has important clinical value for the early detection of lung diseases, assessment of the disease severity, causes identification of dyspnea, and monitoring of critical patients. However, traditional PFT can only be carried out in a hospital environment, and it is challenging to meet the needs for daily and frequent evaluation of chronic respiratory diseases. In this study, we propose a novel method for accurately assessing pulmonary function by analyzing recorded forced cough sounds by mobile device without time and location restrictions. In the experiment, 309 clips of cough sound segments were separated from 133 patients who underwent PFT by using Audacity software. There are 247 clips of training samples and 62 clips of testing samples. Totally 52 features were extracted from the dataset, and principal component analysis (PCA) was used for feature reduction. Combined with biological attributes, the normalized features were regressed by using machine learning models with pulmonary function parameters (i.e., FEV1, FVC, FEV1/FVC, FEV1%, and FVC%). And a 5-fold cross-validation was applied to evaluate the performance of the regression models. As described in the experimental result, the result of coefficient of determination (R2) indicates that the support vector regression (SVR) model performed best in assessing FVC (0.84), FEV1% (0.61), and FVC% (0.62) among these models. The gradient boosting regression (GBR) model performs best in evaluating FEV1 (0.86) and FEV1/FVC (0.54). The result confirmed that the proposed method was capable of accurately assessing pulmonary function with forced cough sound. Besides, the cough sound sampling by a smartphone made it possible to conduct sampling and assess pulmonary function frequently in the home environment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.