Development and implementation of optimized chest CT protocol in COVID-19: A clinical audit.

Radhika H Pandya, Mayur Kiran Shinde, Viral B Patel, Ajay Gajanan Phatak, Himanshu V Pandya

Open access · goldAbstract read
In one paragraph

Article in Journal of family medicine and primary care, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Radhika H PandyaDepartment of Radio Diagnosis, PS Medical College and Shree Krishna Hospital, Bhaikaka University, Karamsad, Gujarat, India.
Mayur Kiran ShindeCentral Research Services, Bhaikaka University, Karamsad, Anand, Gujarat, India.
Viral B PatelDepartment of Radio Diagnosis, PS Medical College and Shree Krishna Hospital, Bhaikaka University, Karamsad, Gujarat, India.
Ajay Gajanan PhatakCentral Research Services, Bhaikaka University, Karamsad, Anand, Gujarat, India.
Himanshu V PandyaDepartment of Medicine and Medical Education, PS Medical College and Shree Krishna Hospital, Bhaikaka University, Karamsad, Gujarat, India.
Bhaikaka UniversityShree Krishna Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Several studies have justified use of chest computed tomography (CT) in diagnosis, evaluation of severity, treatment response, and complications of coronavirus disease 2019 (COVID-19) pneumonia. Increased utilization of CT in patients with known or suspected COVID-19 pneumonia has resulted in concerns of overuse, lack of protocol optimization, and radiation exposure. Aims: The study was conducted to develop and implement optimized protocol for chest CT for reducing radiation dose in adult patients suspected or diagnosed to have COVID-19 infection. Setting and Design: The study was conducted in the department of radiology of a rural tertiary care teaching hospital in western India. Clinical audit was used as a tool to impart and assess the impact of optimized chest CT protocol. Methods and Material: The pre-intervention audit included radiation dosimetry data, number of phases and length of scan of 50 adult patients, undergoing non-contrast chest CT scans in March 2021. A brief educational intervention outlining the parameters of optimized protocol was conducted on April 1, 2021.The post-intervention audit consisted of two cycles for 109 and 67 chest CT scans in the months April and May 2021. Results: The optimized protocol was found clinically adequate with a good inter-rater reliability. The compliance to the optimized protocol was weak in audit cycle 2, which improved significantly in audit cycle 3 after reinforcement. The mean (SD) per scan Computed Tomography Dose Index-Volume (CTDI-vol) reduced significantly across audit cycles [22.06 (12. 31) Vs. 10.58 (7.58) Vs. 4.51 (2.90) milli Gray, respectively, Conclusion: Clinical audit of chest CT protocol and resultant radiation doses provided adequate feedback for dose optimization. A simple educational intervention helped achieve dose optimization.

Indexed as

Chest computed tomographyclinical auditCOVID-19educational intervention

Identifiers

PMID36387664
PMCPMC9648219
OpenAlexW4289209723

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.