Evidence map›Paper›PMID 36385492›Full record

ArticleScientific reports2022

A diagnostic accuracy study on an innovative auto-edge detection technique for identifying simulated implant fractures on radiographic images.

Negar Khosravifard, Bardia Vadiati Saberi, Amir Khosravifard, Hamidreza Zakerjafari, Reihaneh Vafaei, Mohammad Ebrahim Ghaffari

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Negar KhosravifardDepartment of Oral and Maxillofacial Radiology, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran. ngrkhosravi@yahoo.com.ORCID 0000-0002-6746-5991
Bardia Vadiati SaberiDepartment of Periodontics, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.
Amir KhosravifardDepartment of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Hamidreza ZakerjafariDepartment of Dental Prosthesis, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.
Reihaneh VafaeiDepartment of Oral and Maxillofacial Radiology, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.
Mohammad Ebrahim GhaffariDepartment of Biostatistics, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.
Guilan University of Medical Sciences · IRShiraz University · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Implant fracture is a rare but devastating complication of treatment in partially or fully edentulous patients which requires prompt diagnosis. Nevertheless, studies on defining the most accurate technique for the detection of implant fractures are lacking. In the present study, the Canny edge detection algorithm was applied on multiple radiographic modalities including parallel periapical (PPA), oblique periapical (OPA), and cone beam CT (CBCT) with and without metal artifact reduction (MAR) to examine its accuracy for diagnosis of simulated implant fractures. Radiographs were taken from 24 intact implants and 24 implants with artificially created fractures. Images were evaluated in their original and Canny formats. The accuracy of each radiograph was assessed by comparison with a reference standard of direct observation of the implant. The greatest area under the receiver operating characteristic curve belonged to Canny CBCT with MAR (0.958), followed by original CBCT with MAR (0.917), original CBCT without MAR = Canny CBCT without MAR = Canny OPA (0.875), Canny PPA (0.833), original PPA = original OPA (0.792), respectively. The Canny edge detection algorithm is suggested as an innovative method for accurate diagnosis of clinically suspected implant fractures on CBCT and periapical radiographies.

Indexed as

Cone-Beam Computed TomographyFractures, BoneHumansProstheses and ImplantsROC Curve

Identifiers

PMID36385492
PMCPMC9668839
OpenAlexW4309338054

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.