ArticleIEEE transactions on bio-medical engineering2023
MARIE 2.0: A Perturbation Matrix Based Patient-Specific MRI Field Simulator.
Article in IEEE transactions on bio-medical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- An Open-Source Software Toolbox for Rapid Radiofrequency Coil Design and Evaluation in MRI.Magnetic resonance in medicine · 2026Article
- Comparative Assessment of Graglia-Wilton-Peterson and Rao-Wilton-Glisson Basis Functions for Radiofrequency Coil Modeling in Magnetic Resonance Imaging.IEEE journal on multiscale and multiphysics computational techniques · 2026Article
- Global Maxwell Tomography Using the Volume-Surface Integral Equation for Improved Estimation of Electrical Properties.IEEE transactions on bio-medical engineering · 2025Article
- An Optimization Framework for the Design of Radiofrequency Coils for Magnetic Resonance Imaging.bioRxiv : the preprint server for biology · 2025Article
- Local SAR management strategies to use two-channel RF shimming for fetal MRI at 3 T.Magnetic resonance in medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
High static field MR scanners can produce human tissue images of astounding clarity, but rely on high frequency electromagnetic radiation that generates complicated in-tissue field patterns that are patient-specific and potentially harmful. Many such scanners use parallel transmitters to better control field patterns, but then adjust the transmitters based on general guidelines rather than optimizing for the specific patient, mostly because computing patient-specific fields was presumed far too slow. It was recently demonstrated that the combination of fast low-resolution tissue mapping and fast voxel-based field simulation can be used to perform a patient-specific MR safety check in minutes. However, the field simulation required several of those minutes, making it too slow to perform the dozens of simulations that would be needed for patient-specific optimization. In this paper we describe a compressed-perturbation-matrix technique that nearly eliminates the computational cost of including complex coils (or coils and shields) in voxel-based field simulation of tissue, thereby reducing simulation time from minutes to seconds. The approach is demonstrated on a wide variety of head+coil and head+coil+shield configurations, using the implementation in MARIE 2.0, the latest version of the open-source MR field simulator MARIE.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.