ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023
Functional alignment with robotic‑arm assisted total knee arthroplasty demonstrated better patient-reported outcomes than mechanical alignment with manual total knee arthroplasty.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. It is linked to trial NCT06507046 (Robotic Assisted Surgery Comparing Personalized Alignment Versus Mechanical Alignment of Total Knee Arthroplasty - A Randomized Controlled Trial), which is not on this map. Cited by 45 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Robotic Assisted Surgery Comparing Personalized Alignment Versus Mechanical Alignment of Total Knee Arthroplasty - A Randomized Controlled Trial
Who cites it
45 citing papers in PubMed, 5 syntheses or guidelines pooled it.
- Functional alignment in robotic total knee arthroplasty provides favourable outcomes and minimal early revisions: A systematic review and meta-analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Pooled it
- Robotic-assisted total knee arthroplasty: Promise or parity in long-term outcomes?Musculoskeletal surgery · 2026Pooled it
- Robotic-assisted total knee arthroplasty with MAKO is associated with improved functional outcomes : a systematic review and meta-analysis.Bone & joint open · 2025Pooled it
- Robotic assisted Total Knee Arthroplasty (TKA) is not associated with increased patient satisfaction: a systematic review and meta-analysis.International orthopaedics · 2024Pooled it
- Functional alignment in robotic-assisted total knee arthroplasty: a systematic review.Archives of orthopaedic and trauma surgery · 2024Pooled it
- Functional alignment is associated with increased incidence of pre-balance, reduced soft-tissue release, and post-operative pain compared to mechanical alignment in patients undergoing simultaneous bilateral robotic-assisted TKA.Journal of robotic surgery · 2023Trial
- Joint line obliquity change was associated with femoral and tibial resection patterns and smaller final flexion imbalance after robot-assisted total knee arthroplasty.Journal of experimental orthopaedics · 2026Article
- Influence of total knee arthroplasty on coronal plane phenotypes and associated clinical outcomes: a CPAK-based comparison between mechanical and functional alignment.Journal of robotic surgery · 2026Article
- Asia-Pacific expert consensus on robotic-assisted hip and knee arthroplasty.Arthroplasty (London, England) · 2026Review
- Comparison of the Reliability and Gap Differences Between Using the Varus-Valgus Stress Technique and Paddles Technique in Pre-Resection Balancing Phase of Robotic-Assisted Total Knee Arthroplasty.Arthroplasty today · 2026Article
- Comparable outcomes and early revision rates between restricted and unrestricted functional knee positioning in robotic-assisted total knee arthroplasty for varus deformities ≥10°.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Article
- Comparable clinical outcomes in functionally aligned computer-assisted and image-based robotic assisted total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Observational
- Evolving Philosophies of Alignment in TKA: From Mechanical Uniformity to Personalised Harmony.Medicina (Kaunas, Lithuania) · 2026Review
- Article
- Article
- Robotic-assisted restricted kinematic alignment in total knee arthroplasty: A multicenter retrospective assessment of coronal phenotypes and early postoperative outcomes.Journal of experimental orthopaedics · 2026Article
- Article
- [Finite element analysis of tibial and femoral resection configurations on varus alignment in total knee arthroplasty].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025Article
- Three-dimensional verification of osteotomy accuracy in total knee arthroplasty using intraoperative CT imaging: a case series study.BMC musculoskeletal disorders · 2025Article
- Comparable outcomes between cruciate-retaining and posterior-stabilized implants following functionally aligned robotic-assisted total knee arthroplasty for varus knee osteoarthritis.Journal of robotic surgery · 2025Article
Corrections and comments
- Erratum issued
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeGiven the improved accuracy of robot-assisted surgery, robotic-arm assisted functionally aligned total knee arthroplasty (RFA-TKA) aims to preserve the native pre-arthritic knee biomechanics, to achieve balanced flexion-extension gaps. The purpose of this study was to compare the accuracy of the implant position and short-term clinical outcomes of patients who underwent RFA-TKA vs. mechanically aligned total knee arthroplasty with manual technique (MA-TKA).
methodsA prospectively collected database was reviewed retrospectively for patients who underwent primary TKA. Sixty patients who underwent RFA-TKA between February 2020 and July 2020 were included in the RFA-TKA group. Sixty patients who underwent MA-TKA were included via 1:1 matching for age, sex, and body mass index based on the RFA-TKA group. For radiological evaluation, knee X-rays were used to assess the functional knee phenotype and implant position accuracy by measuring the coronal and sagittal alignment, and these measurements were compared between the two groups. Patient demographic characteristics and patient-reported outcomes including Knee Society scores, Western Ontario and McMaster Universities Arthritis Index, and forgotten joint score-12 were compared between the groups.
resultsStatistically significant differences were observed in postoperative 2-year clinical outcomes in favor of RFA-TKA group which showed greater accuracy in the tibial component sagittal alignment than MA-TKA (1.0 ± 2.3 vs. 0.7 ± 1.6, respectively; P < 0.001). However, outliers in the component positions were more common in the MA-TKA group, which was statistically significant for the femoral coronal and tibial sagittal alignments (P = 0.017 and 0.015, respectively).
conclusionsFunctional alignment in TKA could be accurately obtained with the assistance of a robotic arm, and the results showed greater 2 year postoperative patient-reported outcome and satisfaction than mechanically aligned TKA using manual instruments. LEVEL OF EVIDENCE: III.
Indexed as
Identifiers
36378291What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.