Evidence map›Paper›PMID 36377906›Full record

ArticleOrthopaedic surgery2023

Comparison of the Imaging and Clinical Outcomes among the Measured Resection, Gap Balancing, and Hybrid Techniques in Primary Total Knee Arthroplasty.

Kuo Hao, Maozheng Wei, Gang Ji, Yanfeng Jia, Fei Wang

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 2 countries.

Kuo HaoDepartment of Joint Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, People's Republic of China.
Maozheng WeiDepartment of Joint Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, People's Republic of China.
Gang JiDepartment of Joint Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, People's Republic of China.ORCID https://orcid.org/0000-0001-8535-2635
Yanfeng JiaDepartment of Joint Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, People's Republic of China.
Fei WangDepartment of Joint Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, People's Republic of China.ORCID https://orcid.org/0000-0002-4812-9394
Hebei Medical University · CN

Funding

HE BEI health and Health Committee (Medically Applicable Technology Tracking Project1) GZ202002National Natural Science Foundation of China 81873983
6 · The paper itself

Abstract

objectiveAlthough many studies have compared the measured resection (MR) technique to the gap balancing (GB) technique, few studies have investigated the hybrid technique. In this study, we compared imaging and clinical outcomes of the MR, GB, and hybrid techniques in primary total knee arthroplasty (TKA).

methodsFrom January 2016 to January 2019, we conducted a retrospective study on 90 patients who underwent unilateral primary TKA; 30 received the MR technique, 30 received the GB technique, and 30 received the hybrid technique. Radiological outcomes, including joint line level, mechanical alignment of the lower limb, positions of the femoral and tibial components, and rotation of the femoral component, and clinical outcomes, including the visual analog scale score for pain, the Knee Society Score, and the range of motion, were assessed among the three groups. One-way analysis of variance and Dunnett's test were performed for normally distributed data. Kruskal-Wallis H test and Dunn-Bonferroni test were conducted for non-normally distributed data.

resultsNo significant difference in the mechanical alignment (p = 0.151) and the positions of the tibial and femoral components (p = 0.230 for α angle, p = 0.517 for β angle, p = 0.686 for femoral flexion angle, and p = 0.918 for tibial slope angle) was found among the three groups. No significant difference in the elevation of the joint line between the MR and the hybrid groups was found (2.1 ± 0.3 mm vs 2.1 ± 0.1 mm, p = 0.627), but the GB group (2.8 ± 0.2 mm) differed significantly from the other two groups (p < 0.001). Although rotation of the femoral component in the GB group was larger than that of the MR and hybrid groups, the difference was not significant (1.8° ± 0.2° vs 1.7° ± 0.3° vs. 1.7° ± 0.2°, p = 0.101). The clinical outcomes were not significantly different (p > 0.05), although the results in the hybrid group were slightly higher.

conclusionThe hybrid technique helped to restore the mechanical alignment of the lower limb and realize optimal positions of the femoral and tibial components without significant differences relative to the MR and GB techniques. The hybrid technique was more helpful for maintaining the original height of the joint line, which was similar to the MR technique. Additionally, although the improvement in the clinical outcomes in the hybrid group was slightly higher, it was not significantly different among the three groups.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeFemurHumansKnee JointRange of Motion, ArticularRetrospective Studiescomponent alignmentgap balancinghybrid techniquemeasured resectionprimary total knee arthroplasty

Identifiers

PMID36377906
PMCPMC9837215
OpenAlexW4309098870

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.