Evidence map›Paper›PMID 36376783›Full record

ArticleClinical proteomics2022

Determination of temporal reproducibility and variability of cancer biomarkers in serum and EDTA plasma samples using a proximity extension assay.

Troels D Christensen, Emil Maag, Kasper Madsen, Sidsel Christy Lindgaard, Dorte L Nielsen, Julia S Johansen

Open access · goldAbstract read
In one paragraph

Article in Clinical proteomics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.5field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. The Edge Effect in High-Throughput Proteomics: A Cautionary Tale.Journal of the American Society for Mass Spectrometry · 2023
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Troels D ChristensenDepartment of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Borgmester Ib Juuls Vej 1, 2730, Herlev, Denmark. troels.dreier.christensen.01@regionh.dk.
Emil MaagBioXpedia, Aarhus, Denmark.
Kasper MadsenDepartment of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Borgmester Ib Juuls Vej 1, 2730, Herlev, Denmark.
Sidsel Christy LindgaardDepartment of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Borgmester Ib Juuls Vej 1, 2730, Herlev, Denmark.
Dorte L NielsenDepartment of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Borgmester Ib Juuls Vej 1, 2730, Herlev, Denmark.
Julia S JohansenDepartment of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Borgmester Ib Juuls Vej 1, 2730, Herlev, Denmark.
Gentofte Hospital · DKUniversity of Copenhagen · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProximity extension assay (PEA) is a novel antibody-based proteomic technology. Sparse data have been published concerning the matrix effect of serum vs. ethylenediamine tetraacetic acid (EDTA) plasma and the reproducibility of results obtained using PEA technology.

methodsWe analyzed samples with the PEA-based 92-plex Olink® immuno-oncology (I-O) assay. To estimate the matrix effect, we analyzed paired serum and EDTA plasma samples from 12 patients with biliary tract cancer. To evaluate the reproducibility, we used data from 7 studies, where 6-8 serum samples from patients with pancreatic cancer were used as bridging samples on 3 versions of the panel over a 2.5-years period.

resultsFor the study of serum vs. plasma, 80 proteins were evaluable. The mean serum to EDTA plasma ratio ranged from 0.41-3.01. For 36 proteins, the serum and plasma values were not comparable due to high variability of the ratio, poor correlation, or possible concentration effect. For the bridging samples, the mean intra-study inter-assay coefficient of variation (CV) ranged from 11.3% to 26.1%. The mean inter-study CV was 42.0% before normalization and 26.2% after normalization. Inter-study results were well correlated (r ≥ 0.93), especially for studies using the same version of the panel (r ≥ 0.99).

conclusionFor 44 of 92 proteins included in the Olink® I-O panel, the variation between results obtained using serum and EDTA plasma was constant and results were well correlated. Furthermore, samples could be stored for several years and used on different versions of the same PEA panel without it effecting results.

Indexed as

Multiplex ImmunoassaysOlink immuno-oncologyProteinsProximity extension assaySerum-plasma variabilityTumor markers

Identifiers

PMID36376783
PMCPMC9664820
OpenAlexW4308986104

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked