Evidence map›Paper›PMID 36376641›Full record

SynthesisJournal of racial and ethnic health disparities2023

Accuracy of Heart Rate Measurement with Wrist-Worn Wearable Devices in Various Skin Tones: a Systematic Review.

Daniel Koerber, Shawn Khan, Tahmina Shamsheri, Abirami Kirubarajan, Sangeeta Mehta

Open access · bronzeAbstract readSystematic Review
In one paragraph

Synthesis in Journal of racial and ethnic health disparities, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 53 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
53citing papers in PubMed, 4 pooled it
5.4field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

53 citing papers in PubMed, 4 syntheses or guidelines pooled it, 71 citations in OpenAlex.

  1. Pooled it
  2. Atrial fibrillation burden in clinical practice, research, and technology development: a clinical consensus statement of the European Society of Cardiology Council on Stroke and the European Heart Rhythm Association.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Guideline
  3. Pooled it
  4. Pooled it
  5. Guidelines for rigor and reproducibility of heart rate variability within human cardiovascular research.American journal of physiology. Heart and circulatory physiology · 2026
    Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Daniel KoerberFaculty of Medicine, University of Toronto, Toronto, Canada.ORCID 0000-0002-0357-6545
Shawn KhanFaculty of Medicine, University of Toronto, Toronto, Canada.
Tahmina ShamsheriDepartment of Interdisciplinary Studies, McMaster University, Hamilton, Canada.
Abirami KirubarajanFaculty of Medicine, University of Toronto, Toronto, Canada.
Sangeeta MehtaFaculty of Medicine, University of Toronto, Toronto, Canada. geeta.mehta@utoronto.ca.
University of Toronto · CAMcMaster University · CAMount Sinai Hospital · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWearable consumer technology allows for the collection of a growing amount of personal health data. Through the analysis of reflected LED light on the skin, heart rate measurement and arrhythmia detection can be performed. Given that melanin alters skin light absorption, this study seeks to summarize the accuracy of cardiac data from wrist-worn wearable devices for participants of varying skin tones.

methodsWe conducted a systematic review, searching Embase, MEDLINE, CINAHL, and Cochrane for original studies that stratified heart rate and rhythm data for consumer wearable technology according to participant race and/or skin tone.

resultsA total of 10 studies involving 469 participants met inclusion criteria. The frequency-weighted Fitzpatrick score for skin tone was reported in six studies (n = 293), with a mean participant score of 3.5 (range 1-6). Overall, four of the ten studies reported a significant reduction in accuracy of heart rate measurement with wearable devices in darker-skinned individuals, compared to participants with lighter skin tones. Four studies noted no effect of user skin tone on accuracy. The remaining two studies showed mixed results.

conclusionsPreliminary evidence is inconclusive, but some studies suggest that wearable devices may be less accurate for detecting heart rate in participants with darker skin tones. Higher quality evidence is necessary, with larger sample sizes and more objective stratification of participants by skin tone, in order to characterize potential racial bias in consumer devices.

Indexed as

Wearable Electronic DevicesWristHeart RateHumansSkin PigmentationHeart rateHeart rhythmPhotoplethysmographyRacial biasWearable devices

Identifiers

PMID36376641
PMCPMC9662769
OpenAlexW4308963722

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.