Evaluation of three biometric devices: ocular parameters and calculated intraocular lens power.

Rivkah Lender, Devora Mirsky, Riki Greenberger, Zipora Boim, Lee Ben-Yaakov, Chaya Kashtan, Ibrahim Naffar, Shira Shine, Itay Chowers, Hadas Ben-Eli

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2024
    Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Rivkah LenderDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Devora MirskyDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Riki GreenbergerDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Zipora BoimDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Lee Ben-YaakovDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Chaya KashtanDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Ibrahim NaffarDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Shira ShineDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Itay ChowersDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Hadas Ben-EliDepartment of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem, Israel. hadasben@hadassah.org.il.ORCID 0000-0002-2832-4221

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cataract surgery is among the most common medical procedures, and accurate ocular biometry measurements are key for successful visual outcome. The current study evaluated data obtained by the Eyestar 900, Anterion, IOLMaster700 biometers and the Pentacam corneal topographer. Compared values were axial length (AL), anterior chamber depth (ACD), steep- and flat-K, cylinder and axis. Clinical impact was assessed by calculating intraocular lens (IOL) power using the mean values of every parameter and the Barrett and Kane formulas, stratified by device and amount of cylinder. IOL was re-calculated for each device substituting Pentacam K-values. This study included 196 eyes (98 participants) of cataract surgery candidates. When comparing the IOLMaster to the Eyestar (157 eyes), no difference was found in mean AL or ACD measurements (P > 0.05). Steep-K measurements differed between these devices and the Pentacam (P = 0.01). AL and ACD measurements differed between the IOLMaster and Anterion (38 eyes; P < 0.05). Strong correlations (range 0.72-0.99) were found between all four devices. Bland-Altman analysis demonstrated excellent agreement between biometry devices other than ACD between the IOLMaster and Eyestar. Calculated IOL power was 0.50-1.00 diopter (D) lower with the IOLMaster. Cylinder power was 0.75D higher in all biometers when Pentacam K-values were substituted.

Indexed as

CataractLenses, IntraocularAnterior ChamberAxial Length, EyeBiometryHumansProspective StudiesReproducibility of Results

Identifiers

PMID36376354
PMCPMC9663510

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.