Oncology-specific radiation dose and image noise reference levels in adult abdominal-pelvic CT.

Moiz Ahmad, Xinming Liu, Ajaykumar C Morani, Dhakshinamoorthy Ganeshan, Marcus R Anderson, Ehsan Samei, Corey T Jensen

Open access · greenAbstract read
In one paragraph

Article in Clinical imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Moiz AhmadDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, United States of America. Electronic address: MAhmad@mdanderson.org.
Xinming LiuDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, United States of America. Electronic address: XLiu@mdanderson.org.
Ajaykumar C MoraniDepartment of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, United States of America. Electronic address: AMorani@mdanderson.org.
Dhakshinamoorthy GaneshanDepartment of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, United States of America. Electronic address: DGaneshan@mdanderson.org.
Marcus R AndersonDepartment of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, United States of America. Electronic address: MRAnderson@mdanderson.org.
Ehsan SameiCenter for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Clinical Imaging Physics Group, Medical Physics Graduate Program, Departments of Radiology, Physics, Biomedical Engineering, and Electrical and Computer Engineering, Duke University Medical Center, Durham, NC, United States of America. Electronic address: samei@duke.edu.
Corey T JensenDepartment of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, United States of America. Electronic address: cjensen@mdanderson.org.
The University of Texas MD Anderson Cancer Center · USDuke University Hospital · US

Funding

Tumor Evolution and Metastasis ProgramP30CA016672 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI Scott Kopetz · 1985 to 2026
$290.8M
NCI NIH HHS P30 CA016672
6 · The paper itself

Abstract

objectivesTo provide our oncology-specific adult abdominal-pelvic CT reference levels for image noise and radiation dose from a high-volume, oncologic, tertiary referral center.

methodsThe portal venous phase abdomen-pelvis acquisition was assessed for image noise and radiation dose in 13,320 contrast-enhanced CT examinations. Patient size (effective diameter) and radiation dose (CTDI

resultsThe noise reference level was 11.25 HU with a reference range of 10.25-12.25 HU. The dose reference level at a median effective diameter of 30.7 cm was 26.7 mGy with a reference range of 19.6-37.0 mGy. Dose increased with patient size; however, image noise remained approximately constant within the noise reference range. The doses were 2.1-2.5 times than the doses in the ACR DIR registry for corresponding patient sizes. The image noise was 0.63-0.75 times the previously published reference level in abdominal-pelvic CT examinations.

conclusionsOur oncology-specific abdominal-pelvic CT dose reference levels are higher than in the ACR dose index registry and our oncology-specific image noise reference levels are lower than previously proposed image noise reference levels. ADVANCES IN KNOWLEDGE: This study reports reference image noise and radiation dose levels appropriate for the indication of abdomen-pelvis CT examination for cancer diagnosis and staging. The difference in these reference levels from non-oncology-specific CT examinations highlight a need for indication-specific, dose index and image quality reference registries.

Indexed as

PelvisRadiography, AbdominalAbdomenAdultHumansRadiation DosageTomography, X-Ray ComputedCTDiagnostic reference levelsImage noiseOncologyRadiation reduction

Identifiers

PMID36375364
PMCPMC9712239
OpenAlexW4308432142

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.