Evidence map›Paper›PMID 36374883›Full record

ArticleIEEE transactions on bio-medical engineering2023

Characterization of the Targeting Accuracy of a Neuronavigation-Guided Transcranial FUS System In Vitro, In Vivo, and In Silico.

Lu Xu, Christopher P Pacia, Yan Gong, Zhongtao Hu, Chih-Yen Chien, Leqi Yang, H Michael Gach, Yao Hao, Hassanzadeh Comron, Jiayi Huang and 2 more

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 27 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Transcranial Focused Ultrasound Enhances the Discriminative Power of Targeted Voluntary Motor Signals in Humans.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Design and Validation of a Patient-Specific Stereotactic Frame for Transcranial Ultrasound Therapy.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 1 institution in 1 country.

Lu Xu
Christopher P Pacia
Yan Gong
Zhongtao Hu
Chih-Yen Chien
Leqi Yang
H Michael Gach
Yao Hao
Hassanzadeh Comron
Jiayi Huang
Eric C Leuthardt
Hong Chen
Washington University in St. Louis · US

Funding

Image-guided focused ultrasound-mediated intranasal brain drug delivery technique (FUSIN)R01EB027223 · NIBIB · WASHINGTON UNIVERSITY · PI Hong Chen · 2019 to 2026
$4.3M
Focused ultrasound-enabled brain tumor liquid biopsy (FUS-LBx) supplementR01EB030102 · NIBIB · WASHINGTON UNIVERSITY · PI Hong Chen · 2020 to 2026
$4.3M
FOCUS: FUNCTIONAL OPTICAL IMAGING FEEDBACK-CONTROLLED CELLULAR-LEVEL ULTRASOUND STIMULATIONR01MH116981 · NIMH · WASHINGTON UNIVERSITY · PI CHEN, HONG · 2018 to 2021
$2.8M
iSonogenetics for incisionless cell-type-specific neuromodulation of non-human primate brainsUG3MH126861 · NIMH · WASHINGTON UNIVERSITY · PI CHEN, HONG, MONOSOV, ILYA E. · 2021 to 2023
$2.1M
NIBIB NIH HHS R01 EB027223NIBIB NIH HHS R01 EB030102NIMH NIH HHS R01 MH116981NIMH NIH HHS UG3 MH126861
6 · The paper itself

Abstract

Focused ultrasound (FUS)-enabled liquid biopsy (sonobiopsy) is an emerging technique for the noninvasive and spatiotemporally controlled diagnosis of brain cancer by inducing blood-brain barrier (BBB) disruption to release brain tumor-specific biomarkers into the blood circulation. The feasibility, safety, and efficacy of sonobiopsy were demonstrated in both small and large animal models using magnetic resonance-guided FUS devices. However, the high cost and complex operation of magnetic resonance-guided FUS devices limit the future broad application of sonobiopsy in the clinic. In this study, a neuronavigation-guided sonobiopsy device is developed and its targeting accuracy is characterized in vitro, in vivo, and in silico. The sonobiopsy device integrated a commercially available neuronavigation system (BrainSight) with a nimble, lightweight FUS transducer. Its targeting accuracy was characterized in vitro in a water tank using a hydrophone. The performance of the device in BBB disruption was verified in vivo using a pig model, and the targeting accuracy was quantified by measuring the offset between the target and the actual locations of BBB opening. The feasibility of the FUS device in targeting glioblastoma (GBM) tumors was evaluated in silico using numerical simulation by the k-Wave toolbox in glioblastoma patients. It was found that the targeting accuracy of the neuronavigation-guided sonobiopsy device was 1.7 ± 0.8 mm as measured in the water tank. The neuronavigation-guided FUS device successfully induced BBB disruption in pigs with a targeting accuracy of 3.3 ± 1.4 mm. The targeting accuracy of the FUS transducer at the GBM tumor was 5.5 ± 4.9 mm. Age, sex, and incident locations were found to be not correlated with the targeting accuracy in GBM patients. This study demonstrated that the developed neuronavigation-guided FUS device could target the brain with a high spatial targeting accuracy, paving the foundation for its application in the clinic.

Indexed as

Brain NeoplasmsGlioblastomaAnimalsBlood-Brain BarrierBrainMagnetic Resonance ImagingMicrobubblesNeuronavigationSwine

Identifiers

PMID36374883
PMCPMC10176741
OpenAlexW4309095465

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.