Evidence map›Paper›PMID 36374541›Full record

ArticleJMIR formative research2022

Measurement of Vital Signs Using Lifelight Remote Photoplethysmography: Results of the VISION-D and VISION-V Observational Studies.

Emily Heiden, Tom Jones, Annika Brogaard Maczka, Melissa Kapoor, Milan Chauhan, Laura Wiffen, Helen Barham, Jeremy Holland, Manish Saxena, Simon Wegerif and 6 more

3 registry-linked trialsAbstract read
In one paragraph

Article in JMIR formative research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03998098 completednot on this map

A Single-Center Study To Demonstrate the Safety and Performance of Lifelight® First Software Application - A Non-invasive Vital Signs Monitoring Device

TypeobservationalSponsorXim LimitedRan2019 to 2021Enrolled85ConditionsVital SignsArmsOxygen Saturation (Oximetry), Heart Rate (Pulse), Respiratory Rate, Blood Pressure
NCT04763746 completednot on this map

The Measurement of VItal SIgns by Lifelight® Software in comparisON to the Standard of - Multi-site Development: The VISION-MD Study

TypeobservationalSponsorXim LimitedRan2021 to 2023Enrolled1,869ConditionsRespiratory Disorder, Diabetes, Cardiovascular Diseases, Critical CareArmsLifelight Data Collect Sub-protocol 1, Lifelight Data Collect Sub-protocol 2, Lifelight Data Collect Sub-protocol 3, Lifelight Data Collect Sub-protocol 4
NCT07491978 not yet recruitingnot on this mapstarted 2026, after this paper: background citation

Development and Multicenter Validation of an AI-Based Remote Photoplethysmography (rPPG) Facial Scan for Multimodal Health Assessment: Agreement With Clinical, Laboratory, and Psychological Parameters in an Urban Population

Typeobservational_patient_registrySponsorTarumanagara UniversityRan2026 to 2027Enrolled1,000ConditionsMetabolic Syndrome, Hypertension, Diabetes (DM), Tachycardia
3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Observational
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Emily Heiden *Portsmouth Hospitals University NHS Trust, Portsmouth, United Kingdom.ORCID https://orcid.org/0000-0003-4997-065X
Tom Jones *Portsmouth Hospitals University NHS Trust, Portsmouth, United Kingdom.ORCID https://orcid.org/0000-0002-6324-7540
Annika Brogaard MaczkaMind Over Matter Medtech Ltd, London, United Kingdom.ORCID https://orcid.org/0000-0002-6718-2537
Melissa KapoorMind Over Matter Medtech Ltd, London, United Kingdom.ORCID https://orcid.org/0000-0002-1811-2401
Milan ChauhanPortsmouth Hospitals University NHS Trust, Portsmouth, United Kingdom.ORCID https://orcid.org/0000-0001-6242-4587
Laura WiffenPortsmouth Hospitals University NHS Trust, Portsmouth, United Kingdom.ORCID https://orcid.org/0000-0003-3688-7662
Helen BarhamThe Text Doctor, Wantage, United Kingdom.ORCID https://orcid.org/0000-0003-2513-9394
Jeremy HollandXim Ltd, Southampton, United Kingdom.ORCID https://orcid.org/0000-0002-3996-7660
Manish SaxenaBarts NIHR Biomedical Research Centre, Queen Mary University of London, London, United Kingdom.ORCID https://orcid.org/0000-0001-9964-2692
Simon WegerifXim Ltd, Southampton, United Kingdom.ORCID https://orcid.org/0000-0002-3363-6908
Thomas BrownPortsmouth Hospitals University NHS Trust, Portsmouth, United Kingdom.ORCID https://orcid.org/0000-0001-7336-4719
Mitch LomaxSchool of Sport, Health & Exercise Science, University of Portsmouth, Portsmouth, United Kingdom.ORCID https://orcid.org/0000-0003-1381-0398
Heather MasseySchool of Sport, Health & Exercise Science, University of Portsmouth, Portsmouth, United Kingdom.ORCID https://orcid.org/0000-0002-7542-513X
Shahin RostamiData Science Lab, Polyra Limited, Bournemouth, United Kingdom.ORCID https://orcid.org/0000-0001-8977-1239
Laurence PearceXim Ltd, Southampton, United Kingdom.ORCID https://orcid.org/0000-0001-7817-6426
Anoop ChauhanPortsmouth Hospitals University NHS Trust, Portsmouth, United Kingdom.ORCID https://orcid.org/0000-0003-4044-6114

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe detection of early changes in vital signs (VSs) enables timely intervention; however, the measurement of VSs requires hands-on technical expertise and is often time-consuming. The contactless measurement of VSs is beneficial to prevent infection, such as during the COVID-19 pandemic. Lifelight is a novel software being developed to measure VSs by remote photoplethysmography based on video captures of the face via the integral camera on mobile phones and tablets. We report two early studies in the development of Lifelight.

objectiveThe objective of the Vital Sign Comparison Between Lifelight and Standard of Care: Development (VISION-D) study (NCT04763746) was to measure respiratory rate (RR), pulse rate (PR), and blood pressure (BP) simultaneously by using the current standard of care manual methods and the Lifelight software to iteratively refine the software algorithms. The objective of the Vital Sign Comparison Between Lifelight and Standard of Care: Validation (VISION-V) study (NCT03998098) was to validate the use of Lifelight software to accurately measure VSs.

methodsBP, PR, and RR were measured simultaneously using Lifelight, a sphygmomanometer (BP and PR), and the manual counting of RR. Accuracy performance targets for each VS were defined from a systematic literature review of the performance of state-of-the-art VSs technologies.

resultsThe VISION-D data set (17,233 measurements from 8585 participants) met the accuracy targets for RR (mean error 0.3, SD 3.6 vs target mean error 2.3, SD 5.0; n=7462), PR (mean error 0.3, SD 4.0 vs mean error 2.2, SD 9.2; n=10,214), and diastolic BP (mean error -0.4, SD 8.5 vs mean error 5.5, SD 8.9; n=8951); for systolic BP, the mean error target was met but not the SD (mean error 3.5, SD 16.8 vs mean error 6.7, SD 15.3; n=9233). Fitzpatrick skin type did not affect accuracy. The VISION-V data set (679 measurements from 127 participants) met all the standards: mean error -0.1, SD 3.4 for RR; mean error 1.4, SD 3.8 for PR; mean error 2.8, SD 14.5 for systolic BP; and mean error -0.3, SD 7.0 for diastolic BP.

conclusionsAt this early stage in development, Lifelight demonstrates sufficient accuracy in the measurement of VSs to support certification for a Level 1 Conformité Européenne mark. As the use of Lifelight does not require specific training or equipment, the software is potentially useful for the contactless measurement of VSs by nonclinical staff in residential and home care settings. Work is continuing to enhance data collection and processing to achieve the robustness and accuracy required for routine clinical use. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.2196/14326.

Indexed as

algorithmalgorithm developmentblood pressurecontactlessgeneral practicehealth monitoringhealth technologyLifelightphotoplethysmographyremote monitoringremote photoplethysmographysoftwarevital signs/methodsvital signs/standards

Identifiers

PMID36374541
PMCPMC9706384

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials