Evidence map›Paper›PMID 36369527›Full record

ArticleScientific reports2022

Development of wearable multi-lead ECG measurement device using cubic flocked electrode.

Toshihiro Takeshita, Manabu Yoshida, Yusuke Takei, Atsushi Ouchi, Akinari Hinoki, Hiroo Uchida, Takeshi Kobayashi

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Toshihiro TakeshitaSensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, 305-8564, Japan. toshihiro-takeshita@aist.go.jp.
Manabu YoshidaSensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, 305-8564, Japan.
Yusuke TakeiSensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, 305-8564, Japan.
Atsushi OuchiSensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, 305-8564, Japan.
Akinari HinokiGraduate School of Medicine, Nagoya University, Nagoya, 466-8550, Japan.
Hiroo UchidaGraduate School of Medicine, Nagoya University, Nagoya, 466-8550, Japan.
Takeshi KobayashiSensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, 305-8564, Japan.

Funding

JSPS KAKENHI JP20278610
6 · The paper itself

Abstract

This paper describes the fabrication and fundamental evaluation of the cubic flocked electrode (CFE), which is a dry electrode that is fabricated using electrostatic flocking technology. The development of a wearable multi-lead electrocardiogram (ECG) measurement device using the CFE is also reported. To enable the measurement of ECG signals with sufficient quality for medical applications, the occurrence of motion artifacts (MAs) is the most important problem to be overcome. Therefore, it is necessary to stabilize the contact between the patient's skin and the dry electrode. Because the CFE developed in this work offers both contact stability and flexibility, it is expected to enable ECG measurements with low MA levels. In this study, it is demonstrated that the number of MAs caused by respiration can be reduced when the CFE contact is made at a contact pressure of approximately 500 Pa using MA evaluation equipment that was developed in-house. Additionally, a wearable multi-lead ECG is designed and fabricated based on this contact pressure (500 Pa). The results of the demonstration experiment show that the ECG measurements are successful to the same extent as a conventional medical device.

Indexed as

ElectrocardiographyWearable Electronic DevicesArtifactsElectrodesHumansStatic Electricity

Identifiers

PMID36369527
PMCPMC9652328

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.