ArticleScientific reports2022
Development of wearable multi-lead ECG measurement device using cubic flocked electrode.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- A Systematic Review of Design of Electrodes and Interfaces for Non-Contact and Capacitive Biomedical Measurements: Terminology, Electrical Model, and System Analysis.Sensors (Basel, Switzerland) · 2026Pooled it
- Source-level motion artifact suppression in wearable electrodes: From underlying mechanisms to advanced strategies.Materials today. Bio · 2026Review
- A body-scale textile-based electromyogram monitoring system with coaxially shielded conductive yarns.Science advances · 2025Article
- Flexible Bioelectrodes-Integrated Miniaturized System for Unconstrained ECG Monitoring.Sensors (Basel, Switzerland) · 2025Article
- Diagnostic accuracy of wearable ECG and assessment of ventricular repolarization and its cardiovascular risks post cold stress.Scientific reports · 2025Article
- Meso Hybridized Silk Fibroin Watchband for Wearable Biopotential Sensing and AI Gesture Signaling.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Wearable EMG Measurement Device Using Polyurethane Foam for Motion Artifact Suppression.Sensors (Basel, Switzerland) · 2024Article
- Exploring the electrical robustness of conductive textile fasteners for wearable devices in different human motion conditions.Scientific reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
This paper describes the fabrication and fundamental evaluation of the cubic flocked electrode (CFE), which is a dry electrode that is fabricated using electrostatic flocking technology. The development of a wearable multi-lead electrocardiogram (ECG) measurement device using the CFE is also reported. To enable the measurement of ECG signals with sufficient quality for medical applications, the occurrence of motion artifacts (MAs) is the most important problem to be overcome. Therefore, it is necessary to stabilize the contact between the patient's skin and the dry electrode. Because the CFE developed in this work offers both contact stability and flexibility, it is expected to enable ECG measurements with low MA levels. In this study, it is demonstrated that the number of MAs caused by respiration can be reduced when the CFE contact is made at a contact pressure of approximately 500 Pa using MA evaluation equipment that was developed in-house. Additionally, a wearable multi-lead ECG is designed and fabricated based on this contact pressure (500 Pa). The results of the demonstration experiment show that the ECG measurements are successful to the same extent as a conventional medical device.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.