Evidence map›Paper›PMID 36369104›Full record

ArticleKnee surgery & related research2022

Intramedullary rod insertion places the femoral component more laterally during Oxford medial unicompartmental knee arthroplasty.

Toshikazu Tanaka, Yoshihito Suda, Tomoyuki Kamenaga, Akira Saito, Takaaki Fujishiro, Koji Okamoto, Takafumi Hiranaka

Open access · diamondAbstract read
In one paragraph

Article in Knee surgery & related research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Toshikazu TanakaDepartment of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, 1-3-13, Kosobe-Cho, Takatsuki, Osaka, 569-1192, Japan.
Yoshihito SudaDepartment of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, 1-3-13, Kosobe-Cho, Takatsuki, Osaka, 569-1192, Japan.
Tomoyuki KamenagaDepartment of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, 1-3-13, Kosobe-Cho, Takatsuki, Osaka, 569-1192, Japan.
Akira SaitoDepartment of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, 1-3-13, Kosobe-Cho, Takatsuki, Osaka, 569-1192, Japan.
Takaaki FujishiroDepartment of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, 1-3-13, Kosobe-Cho, Takatsuki, Osaka, 569-1192, Japan.
Koji OkamotoDepartment of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, 1-3-13, Kosobe-Cho, Takatsuki, Osaka, 569-1192, Japan.
Takafumi HiranakaDepartment of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, 1-3-13, Kosobe-Cho, Takatsuki, Osaka, 569-1192, Japan. takafumi.hiranaka@gmail.com.ORCID http://orcid.org/0000-0003-4916-6071
Takatsuki General Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aims to assess the influence of intramedullary rods on the implantation positions of femoral components using Microplasty instrumentation in Oxford unicompartmental knee arthroplasty. We hypothesized that femoral components can be laterally implanted incorrectly when using intramedullary rods.

methodsThis prospective study included all 45 consecutive patients (53 knees) who underwent Oxford unicompartmental knee arthroplasty surgery for anteromedial osteoarthritis or spontaneous osteonecrosis of the knee at our hospital during the study period. A custom-made toolset comprising a triangular caliper and circular trial bearings was used to evaluate the distance between the bearing and the vertical wall of the tibia implant (wall-bearing space) using the caliper at 90° flexion both with and without intramedullary rods.

resultsThe wall-bearing space was significantly larger when the intramedullary rod was used than when intramedullary rod was not used (1.8 ± 1.1 mm versus 3.4 ± 1.2 mm, P < 0.001). The mean difference of wall-bearing space with and without intramedullary rod was 1.6 ± 0.7 mm.

conclusionsFemoral components can be laterally implanted incorrectly by an average of 1.6 mm when using intramedullary rods. The wall-bearing space should be evaluated using trial components, and if the relationship is improper, it should be corrected before keel slot preparation.

Indexed as

Bearing dislocationIntramedullary rodOxford unicompartmental knee arthroplastyWall-bearing space

Identifiers

PMID36369104
PMCPMC9652838
OpenAlexW4308914938

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.