Evidence map›Paper›PMID 36367880›Full record

ArticlePloS one2022

Validation of the PICC length prediction formula based on anteroposterior chest radiographs for bedside ultrasound-guided placement.

Youngjong Cho, Sangjoon Lee, Sung-Joon Park, Hyoung Nam Lee, Hwan Hoon Chung

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 5 citations in OpenAlex.

  1. Observational
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Youngjong ChoDepartment of Radiology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Gangwon-do, South Korea.
Sangjoon LeeVascular Center, The Eutteum Orthopedic Surgery Hospital, Paju-si, South Korea.
Sung-Joon ParkDepartment of Radiology, Korea University College of Medicine, Korea University Ansan Hospital, Ansan-si, South Korea.ORCID 0000-0002-1187-7671
Hyoung Nam LeeDepartment of Radiology, Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan-si, South Korea.ORCID 0000-0002-2135-9384
Hwan Hoon ChungDepartment of Radiology, Korea University College of Medicine, Korea University Ansan Hospital, Ansan-si, South Korea.
Korea University · KRSoonchunhyang University · KRUlsan College · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to validate the accuracy of the peripherally inserted central catheter (PICC) length prediction formula using only anteroposterior chest radiographs (AP-CXR) and the technical feasibility of bedside ultrasound-guided PICC placement. This study included 156 Asian adult patients who underwent bedside PICC placement at three hospitals from September 2021 to March 2022. The shortest straight-line distance from the cubital crease to the puncture point (CP) was measured first. Using the formula of a previous study, the CP + estimated PICC length (eCL) was calculated with the parameters measured on AP-CXR. The formula was as follows: 19.409 + 0.424 × (MHTD, maximal horizontal thoracic diameter) + 0.287 × (CL, clavicle length) + 0.203 × (DTV, distance of thoracic vertebrae) + (2VBUs, two vertebral body units below the carina inferior border) (if from the left, 3.063cm was added; if female, 0.997cm was subtracted). Catheters were pretrimmed according to calculated eCL prior to the procedure. Technical success was evaluated, and the validation success of catheter length prediction was classified according to the catheter tip position as follows: optimal position or suboptimal position. Technical success was achieved in 153 cases (98.1%). Evaluation of validation success revealed that the position was "optimal" in 108 cases (70.6%) and "suboptimal" in 45 cases (29.4%). There was no validation failure. There was no case where the catheter was inserted too deep as to wedge into the right atrial wall. In conclusion, the PICC could be positioned accurately using the formula based on only AP-CXR. Furthermore, this bedside procedure was technically feasible.

Indexed as

Catheterization, Central VenousCatheterization, PeripheralCentral Venous CathetersAdultFemaleHumansRadiographyUltrasonography, Interventional

Identifiers

PMID36367880
PMCPMC9651554
OpenAlexW4308791864

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.