Evidence map›Paper›PMID 36366251›Full record

ArticleSensors (Basel, Switzerland)2022

Design and Haemodynamic Analysis of a Novel Anchoring System for Central Venous Pressure Measurement.

Tejaswini Manavi, Masooma Ijaz, Helen O'Grady, Michael Nagy, Jerson Martina, Ciaran Finucane, Faisal Sharif, Haroon Zafar

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Translation of Animal Study to Human: In Silico Based Development of Implantable Pulmonary Artery Pressure Sensor.International journal for numerical methods in biomedical engineering · 2025
    Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 3 countries.

Tejaswini ManaviCardiovascular Research & Innovation Centre, University of Galway, H91 TK33 Galway, Ireland.
Masooma IjazCardiovascular Research & Innovation Centre, University of Galway, H91 TK33 Galway, Ireland.
Helen O'GradyCardiovascular Research & Innovation Centre, University of Galway, H91 TK33 Galway, Ireland.
Michael NagyEndotronix, Inc., Lisle, IL 60532, USA.
Jerson MartinaEndotronix, Inc., Lisle, IL 60532, USA.
Ciaran FinucaneDepartment of Medical Physics and Bioengineering, Mercer's Institute for Successful Ageing, St James's Hospital Dublin, D08 NHY1 Dublin, Ireland.
Faisal SharifCardiovascular Research & Innovation Centre, University of Galway, H91 TK33 Galway, Ireland.
Haroon ZafarCardiovascular Research & Innovation Centre, University of Galway, H91 TK33 Galway, Ireland.
Ollscoil na Gaillimhe – University of Galway · IEEndotronix (United States) · USMercer (Czechia) · CZ

Funding

Enterprise Ireland IP20180755Irish Research Council EPSPG/2020/310
6 · The paper itself

Abstract

BACKGROUND/

objectiveIn recent years, treatment of heart failure patients has proved to benefit from implantation of pressure sensors in the pulmonary artery (PA). While longitudinal measurement of PA pressure profoundly improves a clinician's ability to manage HF, the full potential of central venous pressure as a clinical tool has yet to be unlocked. Central venous pressure serves as a surrogate for the right atrial pressure, and thus could potentially predict a wider range of heart failure conditions. However, it is unclear if current sensor anchoring methods, designed for the PA, are suitable to hold pressure sensors safely in the inferior vena cava. The purpose of this study was to design an anchoring system for accurate apposition in inferior vena cava and evaluate whether it is a potential site for central venous pressure measurement. MATERIALS AND

methodsA location inferior to the renal veins was selected as an optimal site based on a CT scan analysis. Three anchor designs, a 10-strut anchor, and 5-struts with and without loops, were tested on a custom-made silicone bench model of Vena Cava targeting the infra-renal vena cava. The model was connected to a pulsatile pump system and a heated water bath that constituted an in-vitro simulation unit. Delivery of the inferior vena cava implant was accomplished using a preloaded introducer and a dilator as a push rod to deploy the device at the target area. The anchors were subjected to manual compression tests to evaluate their stability against dislodgement. Computational Fluid Dynamics (CFD) analysis was completed to characterize blood flow in the anchor's environment using pressure-based transient solver. Any potential recirculation zones or disturbances in the blood flow caused by the struts were identified.

resultsWe demonstrated successful anchorage and deployment of the 10-strut anchor in the Vena Cava bench model. The 10-strut anchor remained stable during several compression attempts as compared with the other two 5-strut anchor designs. The 10-strut design provided the maximum number of contact points with the vessel in a circular layout and was less susceptible to movement or dislodgement during compression tests. Furthermore, the CFD simulation provided haemodynamic analysis of the optimum 10-strut anchor design.

conclusionsThis study successfully demonstrated the design and deployment of an inferior vena cava anchoring system in a bench test model. The 10-strut anchor is an optimal design as compared with the two other 5-strut designs; however, substantial in-vivo experiments are required to validate the safety and accuracy of such implants. The CFD simulation enabled better understanding of the haemodynamic parameters and any disturbances in the blood flow due to the presence of the anchor. The ability to place a sensor technology in the vena cava could provide a simple and minimally invasive approach for heart failure patients.

Indexed as

Heart FailureVena Cava, InferiorCentral Venous PressureHemodynamicsHumansPulmonary Arteryanchoring systembench testingcentral venous pressurecomputational fluid dynamicshaemodynamic analysisheart failureinferior vena cavaremote patient managementwireless pressure sensor

Identifiers

PMID36366251
PMCPMC9659073
OpenAlexW4308456789

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.