Evidence map›Paper›PMID 36366209›Full record

ArticleSensors (Basel, Switzerland)2022

Dependence of Skin-Electrode Contact Impedance on Material and Skin Hydration.

Krittika Goyal, David A Borkholder, Steven W Day

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed, 1 pooled it
3.7field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed, 1 synthesis or guideline pooled it, 52 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Review
  14. [Study on the electric field transmission characteristics of conducted-electrode tumor treating fields].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Krittika GoyalDepartment of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA.
David A BorkholderDepartment of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA.
Steven W DayDepartment of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA.ORCID 0000-0002-7211-6745
Rochester Institute of Technology · US

Funding

Inconspicuous Daily Monitoring to Reduce Heart Failure HospitalizationsR01NR018301 · NINR · ROCHESTER INSTITUTE OF TECHNOLOGY · PI WANG, LINWEI, ZAREBA, WOJCIECH · 2020 to 2024
$2.8M
NIH HHS R01 NR018301NINR NIH HHS R01 NR018301
6 · The paper itself

Abstract

Dry electrodes offer an accessible continuous acquisition of biopotential signals as part of current in-home monitoring systems but often face challenges of high-contact impedance that results in poor signal quality. The performance of dry electrodes could be affected by electrode material and skin hydration. Herein, we investigate these dependencies using a circuit skin-electrode interface model, varying material and hydration in controlled benchtop experiments on a biomimetic skin phantom simulating dry and hydrated skin. Results of the model demonstrate the contribution of the individual components in the circuit to total impedance and assist in understanding the role of electrode material in the mechanistic principle of dry electrodes. Validation was performed by conducting in vivo skin-electrode contact impedance measurements across ten normative human subjects. Further, the impact of the electrode on biopotential signal quality was evaluated by demonstrating an ability to capture clinically relevant electrocardiogram signals by using dry electrodes integrated into a toilet seat cardiovascular monitoring system. Titanium electrodes resulted in better signal quality than stainless steel electrodes. Results suggest that relative permittivity of native oxide of electrode material come into contact with the skin contributes to the interface impedance, and can lead to enhancement in the capacitive coupling of biopotential signals, especially in dry skin individuals.

Indexed as

ElectrocardiographySkinElectric ImpedanceElectrodesHumansMonitoring, Physiologicbiopotential signalsdry electrodeselectrode materialin-home monitoringskin-electrode contact impedance

Identifiers

PMID36366209
PMCPMC9656728
OpenAlexW4308456249

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.