Evidence map›Paper›PMID 36365965›Full record

ArticleSensors (Basel, Switzerland)2022

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications.

Wen Jiang, David DiPrete, Rusi P Taleyarkhan

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Wen JiangSchool of Nuclear Engineering, Purdue University, W. Lafayette, IN 47907, USA.
David DiPreteSavannah River National Laboratory, Aiken, SC 29808, USA.
Rusi P TaleyarkhanSchool of Nuclear Engineering, Purdue University, W. Lafayette, IN 47907, USA.ORCID 0000-0001-7103-3182

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Polylactic acid (PLA) as a "green," renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1-100 kGy range-of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12-16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0-11 kGy; and to 193 °C for the extended Dg range: 11-120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0-11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0-120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0-16 kGy experiments, and compressed 2 min at 232 °C in the 16-110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0-16 kGy range and from ~0 to ~18% over the 16-114 kGy range. These results provide evidence for utilizing "green"/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5-10%) gamma dosimetry over a wide 0-120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

Indexed as

PolyestersRadiation DosimetersGamma RaysPolymersPolyesterspoly(lactide)Polymersgamma dosimetrymass loss ratio (MLR)polylactic acid (PLA)porosity

Identifiers

PMID36365965
PMCPMC9655317

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.