Evidence map›Paper›PMID 36365944›Full record

ArticleSensors (Basel, Switzerland)2022

A 24 GHz CMOS Direct-Conversion RF Receiver with I/Q Mismatch Calibration for Radar Sensor Applications.

Yongho Lee, Soyeon Kim, Hyunchol Shin

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yongho LeeDepartment of Electronic Convergence Engineering, Kwangwoon University, Seoul 01897, Korea.
Soyeon KimSamsung Electronics Co., Ltd., Suwon 16677, Korea.
Hyunchol ShinDepartment of Electronic Convergence Engineering, Kwangwoon University, Seoul 01897, Korea.ORCID 0000-0003-1141-3428

Funding

Kwangwoon University Exellent Research Program 2022National Research Foundation of Korea 2020R1A2C1008484
6 · The paper itself

Abstract

A 24 GHz millimeter-wave direct-conversion radio-frequency (RF) receiver with wide-range and precise I/Q mismatch calibration is designed in 65 nm CMOS technology for radar sensor applications. The CMOS RF receiver is based on a quadrature direct-conversion architecture. Analytic relations are derived to clearly exhibit the individual contributions of the I/Q amplitude and phase mismatches to the image-rejection ratio (IRR) degradation, which provides a useful design guide for determining the range and resolution of the I/Q mismatch calibration circuit. The designed CMOS RF receiver comprises a low-noise amplifier, quadrature down-conversion mixer, baseband amplifier, and quadrature LO generator. Controlling the individual gate bias voltages of the switching FETs in the down-conversion mixer having a resistive load is found to induce significant changes at the amplitude and phase of the output signal. In the calibration process, the mixer gate bias tuning is first performed for the amplitude mismatch calibration, and the remaining phase mismatch is then calibrated out by the varactor capacitance tuning at the LO buffer's LC load. Implemented in 65 nm CMOS process, the RF receiver achieves 31.5 dB power gain, -35.2 dBm input-referred 1 dB compression power, and 4.8-7.1 dB noise figure across 22.5-26.1 GHz band, while dissipating 106.2 mA from a 1.2 V supply. The effectiveness of the proposed I/Q mismatch calibration is successfully verified by observing that the amplitude and phase mismatches are improved from 1.0-1.5 dB to 0.02-0.19 dB, and from 10.8-23.8 to 1.1-3.2 degrees, respectively.

Indexed as

24 GHzCMOSdirect conversionI/Q mismatch calibrationmillimeter-waveradarRF receiver

Identifiers

PMID36365944
PMCPMC9658703

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.