ArticleMaterials (Basel, Switzerland)2022
Coding Metamaterial Analysis Based on 1-Bit Conventional and Cuboid Design Structures for Microwave Applications.
Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study aimed to investigate the compact 1-bit coding metamaterial design with various conventional and cuboid shapes by analysing the bistatic scattering patterns as well as the monostatic radar cross-section for microwave applications. The construction of this metamaterial design depends on binary elements. For example, 1-bit coding metamaterial comprises two kinds of unit cell to mimic both coding particles such as '0' and '1' with 0° and 180° phase responses. This study adopted a 1 mm × 1 mm of epoxy resin fibre (FR-4) substrate material, which possesses a dielectric constant of 4.3 and tangent loss of 0.025, to construct both elements for the 1-bit coding metamaterial. All simulations were performed using the well-known Computer Simulation Technology (CST) software. The elements were selected via a trial-and-error method based on the phase response properties of the designs. On the other hand, the phase response properties from CST software were validated through the comparison of the phase response properties of both elements with the analytical data from HFSS software. Clear closure was obtained from these findings, and it was concluded that the proposed conventional coding metamaterial manifested the lowest RCS values with an increasing number of lattices. However, the cuboid-shaped design with 20 lattices demonstrated an optimised bistatic scattering pattern of -8.49 dBm
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.