Evidence map›Paper›PMID 36362734›Full record

ArticleJournal of clinical medicine2022

Minimum 10-Year Results of Modular Metal-On-Metal Total Hip Arthroplasty.

Hiroki Wakabayashi, Masahiro Hasegawa, Yohei Naito, Shine Tone, Akihiro Sudo

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Advances in Hip Replacement Surgery.Journal of clinical medicine · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Hiroki WakabayashiDepartment of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu 514-8507, Mie, Japan.ORCID 0000-0003-0371-911X
Masahiro HasegawaDepartment of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu 514-8507, Mie, Japan.
Yohei NaitoDepartment of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu 514-8507, Mie, Japan.
Shine ToneDepartment of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu 514-8507, Mie, Japan.
Akihiro SudoDepartment of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu 514-8507, Mie, Japan.ORCID 0000-0003-0474-4368
Mie University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: this study aimed to assess the long-term outcomes of (a minimum of 10-years) total hip arthroplasty with a metal-on-metal acetabular prosthesis. Methods: Eighty-nine primary total hip arthroplasties (82 patients) were performed using a Pinnacle modular metal-on-metal acetabular prosthesis. Clinical hip function outcomes were evaluated using the Japanese Orthopaedic Association hip score preoperatively and at the final follow-up. Radiological analysis was performed at the final follow-up and magnetic resonance imaging in all hips postoperatively. Results: Out of 82 patients, 17 were excluded who were followed up for <10 years. Of the remaining 65 patients (70 hips), 19 (20 hips) developed pseudotumors during 2−10 years postoperatively. After 10 and 13 years, the survival rates of revision endpoint were 93.6% and 90.4%, respectively. Clinical hip function outcomes had improved significantly at the final follow-up. In the radiological analysis, the mean cup angle of inclination and mean ratio of femoral offset on the operated hip to the contralateral hip was highest in patients with revision surgery for adverse reactions to metal debris. Conclusions: This study showed a 29.0% prevalence of pseudotumors. Some cases required revisions even after 10 years following surgery. Regular clinical surveillance is recommended for the early detection of adverse reactions to metal debris.

Indexed as

long-term resultsmetal-on-metalpseudotumorstotal hip arthroplasty

Identifiers

PMID36362734
PMCPMC9657710
OpenAlexW4308770423

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.