Evidence map›Paper›PMID 36358809›Full record

ArticleCancers2022

Thermography as a Method for Bedside Monitoring of Infantile Hemangiomas.

Juan Antonio Leñero-Bardallo, Begoña Acha, Carmen Serrano, José Antonio Pérez-Carrasco, Juan Ortiz-Álvarez, José Bernabéu-Wittel

Open access · goldAbstract read
In one paragraph

Article in Cancers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Juan Antonio Leñero-BardalloDepartment of Electronics and Electromagnetism, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Seville, Spain.ORCID 0000-0002-1741-9743
Begoña AchaDepartment of Signal Theory and Communications, Universidad de Sevilla, Escuela Técnica Superior de Ingeniería, Camino de los Descubrimientos s/n, 41092 Seville, Spain.ORCID 0000-0001-7838-5746
Carmen SerranoDepartment of Signal Theory and Communications, Universidad de Sevilla, Escuela Técnica Superior de Ingeniería, Camino de los Descubrimientos s/n, 41092 Seville, Spain.ORCID 0000-0003-3008-6231
José Antonio Pérez-CarrascoDepartment of Signal Theory and Communications, Universidad de Sevilla, Escuela Técnica Superior de Ingeniería, Camino de los Descubrimientos s/n, 41092 Seville, Spain.
Juan Ortiz-ÁlvarezDermatology Unit, Virgen de Rocío University Hospital, Av. Manuel Siurot, s/n, 41013 Seville, Spain.
José Bernabéu-WittelDermatology Unit, Virgen de Rocío University Hospital, Av. Manuel Siurot, s/n, 41013 Seville, Spain.
Universidad de Sevilla · ESHospital Universitario Virgen del Rocío · ES

Funding

Ayudas para acciones complementarias de I+D+i, actividades de transferencia de conocimiento AT21_00096Junta de Andalucía (Consejería de Transformación Económica, Industria, Conocimiento y Uni-versidades) P20_01206Junta de Andalucía Proyectos FEDER-US US-1381640Office of Naval Research Global N00014-19-1-2156Plan Estatal de Investigación Retos DPI2016-81103-RPlan Estatal de Investigación Retos RTI2018-097088-B-C31
6 · The paper itself

Abstract

Infantile hemangiomas occur in 3 to 10% of infants. To predict the clinical course and counsel on treatment, it is crucial to accurately determine the hemangiomas' extension, volume, and location. However, this can represent a challenge because hemangiomas may present irregular patterns or be covered by hair, or their depth may be difficult to estimate. Diagnosis is commonly made by clinical inspection and palpation, with physicians basing their diagnoses on visual characteristics such as area, texture, and color. Doppler ultrasonography or magnetic resonance imaging are normally used to estimate depth or to confirm difficult assessments. This paper presents an alternative diagnosis tool-thermography-as a useful, immediate means of carrying out accurate hemangioma examinations. We conducted a study analyzing infantile hemangiomas with a custom thermographic system. In the first phase of the study, 55 hemangiomas of previously diagnosed patients were analyzed with a thermal camera over several sessions. An average temperature variation before and after treatment of -0.19 °C was measured. In the second phase, we selected nine patients and assessed their evolution over nine months by analyzing their thermographic images and implementing dedicated image processing algorithms. In all cases, we found that the thermal image analysis concurred with the independent diagnoses of two dermatologists. We concluded that a higher temperature inside the tumor in the follow-up was indicative of an undesirable evolution.

Indexed as

imaginginfantile hemangiomathermography

Identifiers

PMID36358809
PMCPMC9657513
OpenAlexW4308122999

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.